enow.com Web Search

  1. Ads

    related to: split phase vs capacitor start

Search results

  1. Results from the WOW.Com Content Network
  2. AC motor - Wikipedia

    en.wikipedia.org/wiki/AC_motor

    Schematic of a capacitor start motor. A capacitor start motor is a split-phase induction motor with a starting motor capacitor inserted in series with the startup winding, creating an LC circuit which produces a greater phase shift (and so, a much greater starting torque) than both split-phase and shaded pole motors. This motor has a ...

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The phase shift in Europe is 120°, as is the case with three-phase current. That's why we calculate 130V * √3 = 225V. A three-phase final step-down transformer is then used. One house gets phases A & B, the next house gets phase B & C, the third house gets phase A & C.

  4. Motor capacitor - Wikipedia

    en.wikipedia.org/wiki/Motor_capacitor

    A typical motor start capacitor. A motor capacitor [1] [2] is an electrical capacitor that alters the current to one or more windings of a single-phase alternating-current induction motor to create a rotating magnetic field. [citation needed] There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run ...

  5. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    In a single-phase split-phase motor, reversal is achieved by reversing the connections of the starting winding. Some motors bring out the start winding connections to allow selection of rotation direction at installation. If the start winding is permanently connected within the motor, it is impractical to reverse the sense of rotation.

  6. Centrifugal switch - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_switch

    A variation of the centrifugal switch used a changeover contact to ensure that the auxiliary windings remain in the circuit through a running capacitor. These motors are called two-value or capacitor start capacitor run motors. Centrifugal switches are found in many clothes dryers, supplying power to the motor in parallel with the start switch ...

  7. Capacitor - Wikipedia

    en.wikipedia.org/wiki/Capacitor

    These are called capacitor-start motors, that have relatively high starting torque. Typically they can have up-to four times as much starting torque as a split-phase motor and are used on applications such as compressors, pressure washers and any small device requiring high starting torques.

  1. Ads

    related to: split phase vs capacitor start