enow.com Web Search

  1. Ads

    related to: backflow calibration testing gauge for concrete calculator video

Search results

  1. Results from the WOW.Com Content Network
  2. Schmidt hammer - Wikipedia

    en.wikipedia.org/wiki/Schmidt_hammer

    The test hammer hits the concrete at a defined energy. Its rebound is dependent on the hardness of the concrete and is measured by the test equipment. By reference to a conversion chart, the rebound value can be used to determine the concrete's compressive strength. When conducting the test, the hammer should be held at right angles to the ...

  3. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    There is a variety of manufacturers of these gauges, but most utilize either a three-valve or a five-valve design to test the RPZD in different ways. In the UK , [ 6 ] Illinois, New York , [ 7 ] Texas , [ 8 ] and Missouri ( RsMO 10c60-11 ), the RPZD valve must be tested at least every 12 months by an accredited tester.

  4. Pressure vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Pressure_vacuum_breaker

    A pressure vacuum breaker (PVB) is a type of backflow prevention device, used to keep non-potable (or contaminated) water from entering the water supply. A PVB is similar to an atmospheric vacuum breaker (AVB), except that the PVB contains a spring-loaded poppet. This makes it acceptable for applications that are high hazard or where valves are ...

  5. Load cell - Wikipedia

    en.wikipedia.org/wiki/Load_cell

    A strain gauge sensor measures the deformation of the elastic element, and the output of the sensor is converted by an electronic circuit to a signal that represents the load. Capacitive strain gauges measure the deformation of the elastic material using the change in capacitance of two plates as the plates move closer to each other.

  6. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  7. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    Flow measurement is the quantification of bulk fluid movement. Flow can be measured using devices called flowmeters in various ways. The common types of flowmeters with industrial applications are listed below:

  8. List of measuring instruments - Wikipedia

    en.wikipedia.org/wiki/List_of_measuring_instruments

    feeler gauge: gap widths forward looking infrared (FLIR) detects infrared energy (heat)converts it into an electronic signal, which is then processed to produce a thermal image on a video monitor and perform temperature calculations. framing square: right angles in construction frequency counter: frequency of alternating current: fuel gauge ...

  9. Concrete slump test - Wikipedia

    en.wikipedia.org/wiki/Concrete_slump_test

    The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.

  1. Ads

    related to: backflow calibration testing gauge for concrete calculator video