enow.com Web Search

  1. Ads

    related to: class k fire extinguisher ratings

Search results

  1. Results from the WOW.Com Content Network
  2. Fire extinguisher - Wikipedia

    en.wikipedia.org/wiki/Fire_extinguisher

    Fire extinguishing capacity is rated in accordance with ANSI/UL 711: Rating and Fire Testing of Fire Extinguishers. The ratings are described using numbers preceding the class letter, such as 1-A:10-B:C.

  3. Fire class - Wikipedia

    en.wikipedia.org/wiki/Fire_class

    A fire class is a system of categorizing fire with regard to the type of material and fuel for combustion.Class letters are often assigned to the different types of fire, [1] but these differ between territories; there are separate standards for the United States (NFPA 10 Chapter 5.2.1-5.2.5), Europe (DIN EN2 Classification of fires (European Standard) ISO3941 Classification of fires ...

  4. Fast Flow Extinguishers - Wikipedia

    en.wikipedia.org/wiki/Fast_Flow_Extinguishers

    In other words, a fast flow extinguisher expels a higher volume of agent in less time than a standard compliance flow extinguisher. As a result, fast flow extinguishers have lower UL class A&B ratings than compliance flow extinguishers (the class B numerical rating is the approximate square feet of burning fuel a novice operator could expect to ...

  5. Purple-K - Wikipedia

    en.wikipedia.org/wiki/Purple-K

    Purple-K, also known as PKP, is a dry-chemical fire suppression agent used in some dry chemical fire extinguishers. [1] It is the second most effective dry chemical in fighting class B (flammable liquid) fires after Monnex (potassium allophanate), and can be used against some energized electrical equipment fires (USA class C fires). [2]

  6. ABC dry chemical - Wikipedia

    en.wikipedia.org/wiki/ABC_dry_chemical

    When a Class K / Class F extinguisher is not available an ABC dry chemical extinguisher can be carefully used to control a fire involving cooking oils or fats if the operator is aware of the potential need to re-apply more chemical if the oils or fats reignite. . [1]

  7. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    This rating is the requirement in data safes and vault structures for protecting digital information on magnetic media or hard drives. Temperatures inside the protected chamber must be held below 125 °F (52 °C) for the time period specified, such as Class 125-2 Hour, with temperatures up to 2,000 °F (1,090 °C) outside the vault.

  1. Ads

    related to: class k fire extinguisher ratings