enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pulmonary function testing - Wikipedia

    en.wikipedia.org/wiki/Pulmonary_function_testing

    Lastly, the difference between the two highest values of FEV1 should also be within 150 mL. The highest FVC and FEV1 may be used from each different test. Until the results of three tests meet the criteria of reproducibility, the test can be repeated up to eight times. If it is still not possible to get accurate results, the best three tests ...

  3. Diffusing capacity for carbon monoxide - Wikipedia

    en.wikipedia.org/wiki/Diffusing_capacity_for...

    This test involves measuring the partial pressure difference between inspired and expired carbon monoxide. It relies on the strong affinity and large absorption capacity of red blood cells for carbon monoxide and thus demonstrates gas uptake by the capillaries that are less dependent on cardiac output . [ 3 ]

  4. Spirometry - Wikipedia

    en.wikipedia.org/wiki/Spirometry

    The basic forced volume vital capacity (FVC) test varies slightly depending on the equipment used. It can be in the form of either closed or open circuit. Regardless of differences in testing procedure providers are recommended to follow the ATS/ERS Standardisation of Spirometry. The standard procedure ensures an accurate and objectively ...

  5. Nitrogen washout - Wikipedia

    en.wikipedia.org/wiki/Nitrogen_washout

    A nitrogen washout can be performed with a single nitrogen breath, or multiple ones. Both tests use similar tools, both can estimate functional residual capacity and the degree of nonuniformity of gas distribution in the lungs, but the multiple-breath test more accurately measures absolute lung volumes. [1]

  6. Peak expiratory flow - Wikipedia

    en.wikipedia.org/wiki/Peak_expiratory_flow

    There are a number of non-equivalent scales used in the interpretation of peak expiratory flow. [4] Some examples of Reference Values are given below. There is a wide natural variation in results from healthy test subjects. Wright scale [5] [6] EN 13826 or EU scale [7] NHANESIII [8] reference values provided by the US Centers for Disease ...

  7. Spirometer - Wikipedia

    en.wikipedia.org/wiki/Spirometer

    The American Thoracic Society/European Respiratory Society also recommends race-specific reference values when available. [9] Even today, the National Institute for Occupational Safety and Health’s Spirometry Training Guide that is linked to the Centers for Disease Control and Prevention’s website notes the use of race correction and a race ...

  8. Bullmastiff Is Almost as Big as 'The Grinch' in Hilarious ...

    www.aol.com/bullmastiff-almost-big-grinch...

    Nope it's not Santa waiting to take a photo with you, it's someone more sinister! Thankfully, it doesn't seem like the Bullmastiff lives in Whoville, so he should be okay. If anything, it was the ...

  9. Post bronchodilator test - Wikipedia

    en.wikipedia.org/wiki/Post_bronchodilator_test

    The post bronchodilator test (Post BD), also commonly referred to as a reversibility test, is a test that utilizes spirometry to assess possible reversibility of bronchoconstriction in diseases such as asthma.