Ads
related to: condensate pump continuously running no water pressuresupplyhouse.com has been visited by 100K+ users in the past month
Search results
Results from the WOW.Com Content Network
In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam pressure developed by the boiler. This is usually accomplished through the use of a centrifugal pump. Another common form of feedwater pump runs constantly and is provided with a minimum flow device to stop overpressuring the ...
Large industrial pumps may also serve as the feedwater pump for returning the condensate under pressure to a boiler. Condensate pumps usually run intermittently and have a tank in which condensate can accumulate. Eventually, the accumulating liquid raises a float switch energizing the pump. The pump then runs until the level of liquid in the ...
Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.
The condensate pump then pumps the condensate water through a feedwater heater, which raises the temperature of the water by using extraction steam from various stages of the turbine. [5] [6] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system. [9]
Condensing boilers are water heaters typically used for heating systems that are fueled by gas or oil. When operated in the correct circumstances, a heating system can achieve high efficiency (greater than 90% on the higher heating value) by condensing water vapour found in the exhaust gases in a heat exchanger to preheat the circulating water.
These water treatments often include compounds forming a sludge to entrap such particles; and boilers intended for such water treatment include a structure called a mud drum at the lowest part of the boiler. Bottom blowdown involves periodically opening valves in the mud drum to allow boiler pressure to force accumulated sludge out of the boiler.
The water is heated and then routed into a reduced-pressure flash evaporation "stage" where some of the water flashes into steam. This steam is subsequently condensed into salt-free water. The residual salty liquid from that first stage is introduced into a second flash evaporation stage at a pressure lower than the first stage pressure.
Water cannot flow from the sink to the tap in normal circumstances, even if the water supply loses pressure. An air gap, as related to the plumbing trade, is the unobstructed vertical space between the water outlet and the flood level of a fixture. [1]
Ads
related to: condensate pump continuously running no water pressuresupplyhouse.com has been visited by 100K+ users in the past month