enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Siphon - Wikipedia

    en.wikipedia.org/wiki/Siphon

    For water at standard atmospheric pressure, the maximal siphon height is approximately 10 m (33 feet); for mercury it is 76 cm (30 inches), which is the definition of standard pressure. This equals the maximal height of a suction pump, which operates by the same principle.

  3. Suction pressure - Wikipedia

    en.wikipedia.org/wiki/Suction_pressure

    In refrigeration and air conditioning systems, the suction pressure' (also called the low-side pressure) is the intake pressure generated by the system compressor while operating. The suction pressure, along with the suction temperature the wet bulb temperature of the discharge air are used to determine the correct refrigerant charge in a system.

  4. Vacuum truck - Wikipedia

    en.wikipedia.org/wiki/Vacuum_truck

    An inherent suction limitation of all suction pumps is that they can only lift a liquid through utilizing atmospheric pressure. For pure water the theoretical maximum lift is approximately 10.3 metres (34 ft). [ 4 ]

  5. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.

  6. Vacuum - Wikipedia

    en.wikipedia.org/wiki/Vacuum

    Pressure range Definition The reasoning for the definition of the ranges is as follows (typical circumstances): Prevailing atmospheric pressure (31 kPa to 110 kPa) to 100 Pa low (rough) vacuum Pressure can be achieved by simple materials (e.g. regular steel) and positive displacement vacuum pumps; viscous flow regime for gases

  7. Thermodynamic pump testing - Wikipedia

    en.wikipedia.org/wiki/Thermodynamic_pump_testing

    Thermodynamic pump testing is a form of pump testing where only the temperature rise, power consumed, and differential pressure need to be measured to find the efficiency of a pump. These measurements are typically made with insertion temperature probes and pressure probes fitted to tapping points on the pump's inlet and outlet. [ 1 ]

  8. Suction - Wikipedia

    en.wikipedia.org/wiki/Suction

    Suction is the day-to-day term for the movement of gases or liquids along a pressure gradient with the implication that the movement occurs because the lower pressure pulls the gas or liquid. However, the forces acting in this case do not originate from just the lower pressure side, but also from the side of the higher pressure, as a reaction ...

  9. Choked flow - Wikipedia

    en.wikipedia.org/wiki/Choked_flow

    Choked flow is a limiting condition where the mass flow cannot increase with a further decrease in the downstream pressure environment for a fixed upstream pressure and temperature. For homogeneous fluids, the physical point at which the choking occurs for adiabatic conditions is when the exit plane velocity is at sonic conditions; i.e., at a ...