Search results
Results from the WOW.Com Content Network
The equations for the use of the data retrieved from these tables are very simple. Q= heat gain, usually heat gain per unit time. A= surface area. U= Overall heat transfer coefficient. CLTD= cooling load temperature difference. SCL= solar cooling load factor. CLF= cooling load factor. SC= shading coefficient.
The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...
Load profiles: for heating and cooling demand, electricity profile for equipment and lighting; Energy demand: for heating, cooling, ventilation, light, equipment, auxiliary systems (e.g. pumps, fans, elevators) Daylight availability: in certain zone areas, at different time points with variable outside conditions; Other use of BPS software
Power usage effectiveness. Power usage effectiveness (PUE) or power unit efficiency is a ratio that describes how efficiently a computer data center uses energy; specifically, how much energy is used by the computing equipment (in contrast to cooling and other overhead that supports the equipment). PUE is the ratio of the total amount of energy ...
The starting point in carrying out an estimate both for cooling and heating depends on the exterior climate and interior specified conditions. However, before taking up the heat load calculation, it is necessary to find fresh air requirements for each area in detail, as pressurization is an important consideration.
Thermal management (electronics) 60×60×10 mm straight-finned heat sink with a thermal profile and swirling animated forced convection flow trajectories from a tubeaxial fan, predicted using a CFD analysis package. Free convection thermoelectric cooler (Peltier cooler) with heat sink surface temperature contours, and rising warmer air and ...
Thermal comfort is the condition of mind that expresses subjective satisfaction with the thermal environment. [ 1 ] The human body can be viewed as a heat engine where food is the input energy. The human body will release excess heat into the environment, so the body can continue to operate. The heat transfer is proportional to temperature ...
Sol-air temperature (Tsol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an improvement over: Where: The above equation only takes into account the temperature differences and ignores two important parameters, being 1) solar radiative flux; and 2) infrared ...