enow.com Web Search

  1. Ad

    related to: southwire voltage drop

Search results

  1. Results from the WOW.Com Content Network
  2. Voltage drop - Wikipedia

    en.wikipedia.org/wiki/Voltage_drop

    In electronics, voltage drop is the decrease of electric potential along the path of a current flowing in a circuit. Voltage drops in the internal resistance of the source, across conductors, across contacts, and across connectors are undesirable because some of the energy supplied is dissipated. The voltage drop across the load is proportional ...

  3. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    The voltage changes due to the transition from line-to-line to line-to-earth, typically reducing a 22 kV grid to 12.7 kV SWER or a 33 kV grid to 19.1 kV SWER. The SWER line is a single conductor that may stretch for tens or even hundreds of kilometres, with a number of distribution transformers along its length.

  4. Stray voltage - Wikipedia

    en.wikipedia.org/wiki/Stray_voltage

    Stray voltage. Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations by the normal current flow in the power system. Contact voltage is a better defined term when large voltage ...

  5. Earth potential rise - Wikipedia

    en.wikipedia.org/wiki/Earth_potential_rise

    Earth potential rise. In electrical engineering, earth potential rise (EPR), also called ground potential rise (GPR), occurs when a large current flows to earth through an earth grid impedance. The potential relative to a distant point on the Earth is highest at the point where current enters the ground, and declines with distance from the source.

  6. Aerial bundled cable - Wikipedia

    en.wikipedia.org/wiki/Aerial_bundled_cable

    Aerial bundled cable. In Old Coulsdon, Surrey. Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. This contrasts with the traditional practice of using uninsulated conductors separated by air gaps.

  7. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The three bars for the three "live" phases (marked L1, L2 and L3) are also visible on the bottom right. In electrical engineering, ground and neutral (earth and neutral) are circuit conductors used in alternating current (AC) electrical systems. The neutral conductor receives and returns alternating current to the supply during normal operation ...

  8. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    Leakage reactance is usually the most important element of a power system transformer due to power factor, voltage drop, reactive power consumption and fault current considerations. [1] [2] Leakage inductance depends on the geometry of the core and the windings.

  9. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A split-phase or single-phase three-wire system is a type of single-phase electric power distribution. It is the alternating current (AC) equivalent of the original Edison Machine Works three-wire direct-current system. Its primary advantage is that, for a given capacity of a distribution system, it saves conductor material over a single-ended ...

  1. Ad

    related to: southwire voltage drop