enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. File:Submersible-pump System.svg - Wikipedia

    en.wikipedia.org/wiki/File:Submersible-pump...

    Endorse this file for transfer by adding |human=<your username> to this Template.; If this file is freely licensed, but otherwise unsuitable for Commons (e.g. out of Commons' scope, still copyrighted in the US), then replace this Template with {{Do not move to Commons|reason=<Why it can't be moved>}}

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...

  5. Submersible pump - Wikipedia

    en.wikipedia.org/wiki/Submersible_pump

    A 0.75 HP bore-well submersible pump which had been used to pump groundwater One style of submersible pump for industrial use. Outlet pipe and electrical cable not connected. A submersible pump (or electric submersible pump (ESP) is a device which has a hermetically sealed motor close-coupled to the pump body. The whole assembly is submerged in ...

  6. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Phasor diagram showing 240 V delta and center-tapped phase (a–c) creating two 120 V pairs. Consider the low-voltage side of a 120/240 V high leg delta connected transformer, where the b phase is the high leg. The line-to-line voltage magnitudes are all the same: = = =.

  7. Two-wire circuit - Wikipedia

    en.wikipedia.org/wiki/Two-wire_circuit

    Two-wire circuits in new installations are limited to intercom and military field telephone applications, though these too are being supplanted by modern digital communication modes. To communicate in both directions in the same wire pair, conversion between four-wire and two-wire was necessary, both at the telephone and at the central office .

  8. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    NEMA 1-15P (two-pole, no ground) and NEMA 5-15P (two-pole with ground pin) plugs are used on common domestic electrical equipment, and NEMA 5-15R is the standard 15-ampere electric receptacle (outlet) found in the United States, and under relevant national standards, in Canada (CSA C22.2 No. 42 [1]), Mexico (NMX-J-163-ANCE) and Japan (JIS C 8303).

  9. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.