Doppler echocardiography is a procedure that uses Doppler ultrasonography to examine the heart. [1] An echocardiogram uses high frequency sound waves to create an image of the heart while the use of Doppler technology allows determination of the speed and direction of blood flow by utilizing the Doppler effect .
A transthoracic echocardiogram (TTE) is the most common type of echocardiogram, which is a still or moving image of the internal parts of the heart using ultrasound. In this case, the probe (or ultrasonic transducer ) is placed on the chest or abdomen of the subject to get various views of the heart.
It is a type of medical imaging, using standard ultrasound or Doppler ultrasound. [1] The visual image formed using this technique is called an echocardiogram, a cardiac echo, or simply an echo. Echocardiography is routinely used in the diagnosis, management, and follow-up of patients with any suspected or known heart diseases. It is one of the ...
From these, it is easy to calculate the area (in cm 2) of the aortic valve by simply dividing the LV stroke volume (in cm 3) by the AV VTI (in cm) measured on the spectral Doppler display using continuous-wave Doppler. [citation needed] Stroke volume = 0.785(π/4) x Diameter 2 x VTI of LVOT Cross sectional area of LVOT = 0.785(π/4) x LVOT ...
Doppler ultrasonography of the kidney is widely used, and the vessels are easily depicted by the color Doppler technique in order to evaluate perfusion. Applying spectral Doppler to the renal artery and selected interlobular arteries, peak systolic velocities, resistive index, and acceleration curves can be estimated (Figure 4) (e.g., peak ...
Doppler echocardiography is the use of Doppler ultrasonography to examine the heart. [13] An echocardiogram can, within certain limits, produce an accurate assessment of the direction of blood flow and the velocity of blood and cardiac tissue at any arbitrary point using the Doppler effect. One of the limitations is that the ultrasound beam ...
The cardiac index (CI) is a hemodynamic measure that represents the cardiac output (CO) of an individual divided by their body surface area (BSA), expressed in liters per minute per square meter (L/min/m²). This parameter provides a more accurate assessment of heart function relative to the size of the individual, as opposed to absolute ...
Velocity Time Integral is a clinical Doppler ultrasound measurement of blood flow, equivalent to the area under the velocity time curve. The product of VTI (cm/stroke) and the cross sectional area of a valve (cm2) yields a stroke volume (cm3/stroke), which can be used to calculate cardiac output.