enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy is an American National Standard published by ASHRAE that establishes the ranges of indoor environmental conditions to achieve acceptable thermal comfort for occupants of buildings. It was first published in 1966, and since 2004 has been updated every three to six years.

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLTD/CLF/SCL (cooling load temperature difference/cooling load factor/solar cooling load factor) cooling load calculation method was first introduced in the 1979 ASHRAE Cooling and Heating Load Manual (GRP-158) [1] The CLTD/CLF/SCL Method is regarded as a reasonably accurate approximation of the total heat gains through a building envelope ...

  4. List of refrigerants - Wikipedia

    en.wikipedia.org/wiki/List_of_refrigerants

    According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.

  5. Thermal comfort - Wikipedia

    en.wikipedia.org/wiki/Thermal_comfort

    Thermal comfort calculations in accordance with the ANSI/ASHRAE Standard 55, [1] the ISO 7730 Standard [7] and the EN 16798-1 Standard [8] can be freely performed with either the CBE Thermal Comfort Tool for ASHRAE 55, [9] with the Python package pythermalcomfort [10] or with the R package comf.

  6. ASHRAE Handbook - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_Handbook

    The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...

  7. Operative temperature - Wikipedia

    en.wikipedia.org/wiki/Operative_temperature

    Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...

  8. Table of specific heat capacities - Wikipedia

    en.wikipedia.org/wiki/Table_of_specific_heat...

    A Assuming an altitude of 194 metres above mean sea level (the worldwide median altitude of human habitation), an indoor temperature of 23 °C, a dewpoint of 9 °C (40.85% relative humidity), and 760 mmHg sea level–corrected barometric pressure (molar water vapor content = 1.16%).

  9. List of Canadian natural gas companies - Wikipedia

    en.wikipedia.org/wiki/List_of_Canadian_natural...

    This is a list of Canadian natural gas companies: ATCO - based in Edmonton, Alberta [1] AltaGas - based in Calgary, Alberta; Anderson; Canadian Natural Resources - based in Calgary; Dejour Energy - based in British Columbia; Direct Energy - formerly based in Toronto and now based in Houston, Texas

  1. Related searches ashrae 55 calculation chart for food grade gas suppliers in canada list

    ashrae 55 calculationashrae 55 air speed
    ashrae 55 pdfashrae 55 scope
    ashrae 55 temperature