  2. Electrical resistivities of the elements (data page) - Wikipedia

    en.wikipedia.org/wiki/Electrical_resistivities_of...

    As quoted in an online version of: David R. Lide (ed), CRC Handbook of Chemistry and Physics, 84th Edition.CRC Press. Boca Raton, Florida, 2003; Section 4, Properties of the Elements and Inorganic Compounds; Physical Properties of the Rare Earth Metals

  3. Electrical resistivity and conductivity - Wikipedia

    en.wikipedia.org/wiki/Electrical_resistivity_and...

    For example, for long-distance overhead power lines, aluminium is frequently used rather than copper (Cu) because it is lighter for the same conductance. Silver, although it is the least resistive metal known, has a high density and performs similarly to copper by this measure, but is much more expensive.

  4. Sheet resistance - Wikipedia

    en.wikipedia.org/wiki/Sheet_resistance

    This is an advantage, because sheet resistance of 1 Ω could be taken out of context and misinterpreted as bulk resistance of 1 ohm, whereas sheet resistance of 1 Ω/sq cannot thus be misinterpreted. The reason for the name "ohms per square" is that a square sheet with sheet resistance 10 ohm/square has an actual resistance of 10 ohm ...

  5. Aluminium–copper alloys - Wikipedia

    en.wikipedia.org/wiki/Aluminiumcopper_alloys

    Aluminium–copper alloys (AlCu) are aluminium alloys that consist largely of aluminium (Al) and traces of copper (Cu) as the main alloying elements. Important grades also contain additives of magnesium , iron , nickel and silicon ( AlCu(Mg, Fe, Ni, Si) ), often manganese is also included to increase strength (see aluminium-manganese alloys ).

  6. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    [5]: 27 For an arbitrary gauge n, it's approximately 10 n/10 Ω per 10 000 ft. Because aluminum wire has a conductivity of approximately 61% of copper, an aluminum wire has nearly the same resistance as a copper wire that is two sizes smaller, which has 62.9% of the area.

  7. 2024 aluminium alloy - Wikipedia

    en.wikipedia.org/wiki/2024_aluminium_alloy

    2024 aluminium alloy is an aluminium alloy, with copper as the primary alloying element. It is used in applications requiring a high strength-to-weight ratio, as well as good fatigue resistance. It is weldable only through friction welding , and has average machinability .

  8. Copper conductor - Wikipedia

    en.wikipedia.org/wiki/Copper_conductor

    Copper's higher tensile strength (200–250 N/mm 2 annealed) compared to aluminium (100 N/mm 2 for typical conductor alloys [16]) is another reason why copper is used extensively in the building industry. Copper's high strength resists stretching, neck-down, creep, nicks and breaks, and thereby also prevents failures and service interruptions. [17]

  9. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC.