Search results
Results from the WOW.Com Content Network
An inclinometer or clinometer is an instrument used for measuring angles of slope, elevation, or depression of an object with respect to gravity's direction. It is also known as a tilt indicator , tilt sensor , tilt meter , slope alert , slope gauge , gradient meter , gradiometer , level gauge , level meter , declinometer , and pitch & roll ...
In 1914 and 1915, the Forestry Quarterly published a series of articles on the use of the Abney level. [6] [7] [8] These tutorial articles remain useful today, but the primary reference for usage is the 1927 Abney Level Handbook. [3] The Abney level is typically used at the eye height of the surveyor, either hand-held or mounted on a staff at ...
Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.
Altitude – The plain quadrant with plumb line, used to take the altitude of an object. Gunner's – A type of clinometer used by an artillerist to measure the elevation or depression angle of a gun barrel of a cannon or mortar, both to verify proper firing elevation, and to verify the correct alignment of the weapon-mounted fire control devices.
Multi-color images of several types of fluorophores must be composed by combining several single-color images. [1] Most fluorescence microscopes in use are epifluorescence microscopes, where excitation of the fluorophore and detection of the fluorescence are done through the same light path (i.e. through the objective).
It can be used as an imaging technique in confocal microscopy, two-photon excitation microscopy, and multiphoton tomography. The fluorescence lifetime (FLT) of the fluorophore, rather than its intensity, is used to create the image in FLIM. Fluorescence lifetime depends on the local micro-environment of the fluorophore, thus precluding any ...
The light path of a bright-field microscope is extremely simple; no additional components are required beyond the normal light-microscope setup. The light path begins at the illuminator or the light source on the base of the microscope. Often a halogen lamp is used.
A simple scale hypsometer allows the height of a building or tree to be measured by sighting across a ruler to the base and top of the object being measured, when the distance from the object to the observer is known.