enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fire alarm control panel - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_control_panel

    A fire alarm control panel (FACP), fire alarm control unit (FACU), fire indicator panel (FIP), or simply fire alarm panel is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operational integrity, and provides for automatic control of equipment, and ...

  3. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Power system protection is a branch of electrical power engineering that deals with the protection of electrical power systems from faults [citation needed] through the disconnection of faulted parts from the rest of the electrical network. The objective of a protection scheme is to keep the power system stable by isolating only the components ...

  4. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The phase shift in Europe is 120°, as is the case with three-phase current. That's why we calculate 130V * √3 = 225V. A three-phase final step-down transformer is then used. One house gets phases A & B, the next house gets phase B & C, the third house gets phase A & C.

  5. Hypoxic air technology for fire prevention - Wikipedia

    en.wikipedia.org/wiki/Hypoxic_air_technology_for...

    Hypoxic air technology for fire prevention, also known as oxygen reduction system (ORS), is an active fire protection technique based on a permanent reduction of the oxygen concentration in the protected rooms. Unlike traditional fire suppression systems that usually extinguish fire after it is detected, hypoxic air is able to prevent fire.

  6. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    In 2002, the NEC removed the word "receptacle", leaving "outlets", with the effect that lights and other wired-in devices such as ceiling fans within bedrooms were added to the requirement. The 2005 code made it clearer that all outlets must be protected despite discussion in the code-making panel about excluding bedroom smoke detectors from ...

  7. Zero-crossing control - Wikipedia

    en.wikipedia.org/wiki/Zero-crossing_control

    Zero-crossing control (or burst-fire control) is an approach for electrical control circuits that starts operation with the AC load voltage at close to 0 volts in the AC cycle. [1] This is in relation to solid-state relays, such as TRIACs and silicon controlled rectifiers . [ 1 ]

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Electric power system - Wikipedia

    en.wikipedia.org/wiki/Electric_power_system

    A steam turbine used to provide electric power. An electric power system is a network of electrical components deployed to supply, transfer, and use electric power. An example of a power system is the electrical grid that provides power to homes and industries within an extended area.