Search results
Results from the WOW.Com Content Network
For end-bearing piles, drilling continues until the borehole has extended a sufficient depth (socketing) into a sufficiently strong layer. Depending on site geology, this can be a rock layer, or hardpan, or other dense, strong layers. Both the diameter of the pile and the depth of the pile are highly specific to the ground conditions, loading ...
Anchor piles are typically designed to resist both horizontal and vertical loads. The axial holding capacity of the anchor pile is due to the friction along the pile-soil interface, while the lateral capacity of the pile is generated by lateral soil resistance, where the anchor's orientation is critical to optimising this resistance.
Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...
Franki piles can be used as high-capacity deep foundation elements without the necessity of excavation or dewatering. [4] They are useful in conditions where a sufficient bearing soil can only be reached deeper in the ground, [5] [6] and are best suited to granular soil where bearing is primarily achieved from the densification of the soil around the base. [4]
Schematic cross section of a pressurized caisson. In geotechnical engineering, a caisson (/ ˈ k eɪ s ən,-s ɒ n /; borrowed from French caisson 'box', from Italian cassone 'large box', an augmentative of cassa) is a watertight retaining structure [1] used, for example, to work on the foundations of a bridge pier, for the construction of a concrete dam, [2] or for the repair of ships.
There are a number of methods for the construction of shafts, the most significant being: The use of sheet piles, diaphragm walls or bored piles to construct a square or rectangular braced shaft; The use of segmental lining installed by underpinning or caisson sunk to form a circular shaft
Static load testing is an in situ type of load testing used in geotechnical investigation to determine the bearing capacity of deep foundations prior to the construction of a building. It differs from the statnamic load test and dynamic load testing in that the pressure applied to the pile is slower.
Timber-frame building showing considerable, but tolerable, settlement. Settlement is the downward movement or the sinking of a structure's foundation.It is mostly caused by changes in the underlying soil, such as drying and shrinking, wetting and softening, or compression due to the soil being poorly compacted when construction started. [1]