enow.com Web Search

  1. Ads

    related to: what is ducted air conditioning not cooling 2nd floor

Search results

  1. Results from the WOW.Com Content Network
  2. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor diffusers), located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone. [1]

  3. Plenum space - Wikipedia

    en.wikipedia.org/wiki/Plenum_space

    Vertical section through a commercial building using HVAC plenum instead of airspace plenum. When both the supply and return ducts are constructed in this manner, it is possible to insulate the ducts and the dropped ceiling so that the upper airspace is not heated or cooled, increasing energy efficiency. This is a fully enclosed plenum.

  4. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    The condenser is the hot side of an air conditioner or heat pump. Condensers are heat exchangers, and can transfer heat to air or to an intermediate fluid (such as water or an aqueous solution of ethylene glycol) to carry heat to a distant sink, such as ground (earth sink), a body of water, or air (as with cooling towers). constant air volume

  5. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    A floor register. A register is a grille with moving parts, capable of being opened and closed and the air flow directed, which is part of a building's heating, ventilation, and air conditioning (HVAC) system. The placement and size of registers is critical to HVAC efficiency.

  6. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...

  7. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    Air conditioning can be achieved using a mechanical 'air conditioner' or by other methods, including passive cooling and ventilative cooling. [ 2 ] [ 3 ] Air conditioning is a member of a family of systems and techniques that provide heating, ventilation, and air conditioning (HVAC) . [ 4 ]

  8. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).

  9. Chilled beam - Wikipedia

    en.wikipedia.org/wiki/Chilled_beam

    A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. [1] This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements.

  1. Ads

    related to: what is ducted air conditioning not cooling 2nd floor