The tension failure loads predicted by the CCD method fits experimental results over a wide range of embedment depth (e.g. 100 – 600 mm). [2] Anchor load bearing capacity provided by ACI 349 does not consider size effect, thus an underestimated value for the load-carrying capacity is obtained for large embedment depths.
ACI 318 Building Code Requirements for Structural Concrete provides minimum requirements necessary to provide public health and safety for the design and construction of structural concrete buildings. [6] It is issued and maintained by the American Concrete Institute. [7] The latest edition of the code is ACI 318-19.
The ACI Building Code Requirements put the following restrictions on amount of spiral reinforcement. ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in.
In structural and mechanical engineering, the shear strength of a component is important for designing the dimensions and materials to be used for the manufacture or construction of the component (e.g. beams, plates, or bolts). In a reinforced concrete beam, the main purpose of reinforcing bar (rebar) stirrups is to increase the shear strength.
Mohr–Coulomb theory is a mathematical model (see yield surface) describing the response of brittle materials such as concrete, or rubble piles, to shear stress as well as normal stress. Most of the classical engineering materials follow this rule in at least a portion of their shear failure envelope.
The effective reinforcement ratio was determined from the maximum arching moment of resistance in a rigidly restrained concrete slab, which Rankin [21] had derived for laterally restrained concrete slabs from McDowell, McKee and Sevin's [22] arching action deformation theory for masonry walls.
In reinforced concrete buildings, masonry infill walls are considered non-structural elements, but damage to infills can lead to large repair costs and change the behaviour of a structure, even leading to aforementioned soft-storey or beam-column joint shear failures. Local failure of the infill panels due to in and out-of-plane mechanisms, but ...
From a designer's point of view, steel plate walls have become a very attractive alternative to other steel systems, or to replace reinforced concrete elevator cores and shear wall. In comparative studies it has been shown that the overall costs of a building can be reduced significantly when considering the following advantages: [5]