A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
Tamper-resistant GFCI duplex receptacle type 5-20RA, which can take 5-15 and 5-20 grounding plugs and 1-15 non-grounding plugs. These versions of the 5-15R or 5-20R receptacle are residual-current devices, and have "Test" and "Reset" buttons (and sometimes an indicator light which may be normally on or normally off per the vendor's design). In ...
One GFCI receptacle can serve as protection for several downstream conventional receptacles. GFCI devices come in many configurations including circuit-breakers, portable devices and receptacles. Another safety device introduced with the 1999 code is the arc-fault circuit interrupter (AFCI). This device detects arcs from hot to neutral that can ...
There are several alternatives for connecting newer appliances to two-prong receptacles without rewiring the building: removing the grounding pin of the plug (unsafe), replacing the receptacle with a three-prong outlet (unsafe without proper ground), or replacing the receptacle with a Ground Fault Circuit Interrupter (GFCI).
This device, which can be a circuit breaker or the first outlet on a circuit, is designed to detect hazardous electrical arcing in the branch circuit wiring as well as in cords and plugs. An AFCI device is designed to trip quickly when it detects potentially dangerous arcing that could start a fire, but not trip with harmless arcing as part of ...
NEMA 1-15 polarised plug NEMA 1-15 unpolarised plug. NEMA-1 plugs have two parallel blades and are rated 15 A at 125 volts. They provide no ground connection but will fit into a grounding NEMA 5-15 receptacle. Early versions were not polarised, but most plugs are polarised today via a wider neutral blade.
Having a distinct connector designated for dimmable power also helps prevent confusion of dimmed and non-dimmed circuits which could lead to equipment damage. Even the smallest stage pin connectors are rated for 20 A, which translates to 2.4 kW at 120 V, compared to the 15 A and 1.8 kW of the NEMA 5-15.
Multiple 5 A sockets might be on a 15 A circuit, or each on a dedicated 5 A circuit. Lighting circuits fused at 5 A were generally used to feed the 2 A sockets. Adaptors were available from 15 A down to 5 A and from 5 A down to 2 A so in practice it was possible for an appliance with the smallest size of flex to be protected only by a 15 A fuse.