A high-voltage current transformer may contain several cores, each with a secondary winding, for different purposes (such as metering circuits, control, or protection). [7] A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer.
Diagram of center-tapped transformer. In electronics, a center tap (CT) is a contact made to a point halfway along a winding of a transformer or inductor, or along the element of a resistor or a potentiometer. Taps are sometimes used on inductors for the coupling of signals, and may not necessarily be at the half-way point, but rather, closer ...
Interactive data transformation (IDT) [13] is an emerging capability that allows business analysts and business users the ability to directly interact with large datasets through a visual interface, [9] understand the characteristics of the data (via automated data profiling or visualization), and change or correct the data through simple ...
Transformer architecture is now used alongside many generative models that contribute to the ongoing AI boom. In language modelling, ELMo (2018) was a bi-directional LSTM that produces contextualized word embeddings, improving upon the line of research from bag of words and word2vec. It was followed by BERT (2018), an encoder-only Transformer ...
This is a common method used in portable current measuring instruments but permanent installations use more economical types of the current transformer. Specially constructed wideband CTs are also used, usually with an oscilloscope , to measure high frequency waveforms or pulsed currents within pulsed power systems.
Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2. The centre-tapped side of T1 is connected between two of the phases on the three-phase side.
where A is the cross-sectional area of the coil and N is the number of turns. The Rogowski coil has a low sensitivity due to the absence of a high permeability magnetic core that the current transformer can take advantage of. However, this can be compensated for by adding more turns on the Rogowski coil or using an integrator with a higher gain k.
Transformer winding primary (usually high-voltage) connecting wires are of many types. They may be labeled as H 1, H 2 (sometimes H 0 if it is internally designed to be grounded) and X 1, X2 and sometimes an X 3 tap may be present. Sometimes a second isolated winding (Y 1, Y 2, Y 3) (and third (Z 1, Z 2, Z 3) may also be available on the same ...