Search results
Results from the WOW.Com Content Network
Each phase of the circuit is run in a separate grounded metal enclosure. The only fault possible is a phase-to-ground fault, since the enclosures are separated. This type of bus can be rated up to 50,000 amperes and up to hundreds of kilovolts (during normal service, not just for faults), but is not used for building wiring in the conventional ...
Ceramic cleats, which were block-shaped pieces, served a purpose similar to that of the knobs except that cleats were generally used in places where the wiring was surface mounted. Not all knob and tube installations utilized cleats. Ceramic bushings protected each wire entering a metal device box, when such an enclosure was used.
FMT is a raceway, but not a conduit and is described in a separate NEC Article 360. It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes. NEC 360.2 describes it as: "A raceway that is circular in cross section, flexible, metallic and liquidtight without a nonmetallic jacket."
NEC 2008 400.22(f) allows surface marking with ridged, grooves or white stripes on the surface of lamp cord. With transparent cord the hot wire is copper colored, and the neutral is silver colored. Grounding wire of circuit may be bare or identified insulated wire of green or green having yellow stripes. All metallic systems in a building are ...
Unfortunately, CU/AL switches and receptacles failed to work well enough with aluminum wire, and a new specification called CO/ALR (meaning copper-aluminum, revised) was created. These devices employ brass screw terminals that are designed to act as a similar metal to aluminum and to expand at a similar rate, and the screws have even deeper ...
AC power plugs are also commonly circular, for example, Schuko plugs and IEC 60309. NMEA 2000 cabling using M12 connectors. The M12 connector, specified in IEC 61076-2-101, is a circular electrical plug/receptacle pair with 12mm OD mating threads, used in NMEA 2000, DeviceNet, IO-Link, some kinds of Industrial Ethernet, etc. [16] [17]
The communication only goes sequentially, as there is no addressing. Instead the machine's SMEMA cables connect to each other's upstream or downstream plug. The plugs and wires are multimate connectors and receptacles consisting of 14 wire connections. However, only 4 wires are used for data, while the 8th pin connection is the shielding.
Wireline truck rigged up to a drilling rig in Canada. In the oil and gas industry, the term wireline usually refers to the use of multi-conductor, single conductor or slickline cable, or "wireline", as a conveyance for the acquisition of subsurface petrophysical and geophysical data and the delivery of well construction services such as pipe recovery, perforating, plug setting and well ...