For comparison, phenolic foam insulation has a k-value of around 0.018 W/(m⋅K), [23] while wood varies anywhere from 0.15 to 0.75 W/(m⋅K), and steel has a k-value of approximately 50.0 W/(m⋅K). These figures vary from product to product, so the UK and EU have established a 90/90 standard which means that 90% of the product will conform to ...
The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]
This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...
The SI unit of absolute thermal resistance is kelvins per watt (K/W) or the equivalent degrees Celsius per watt (°C/W) – the two are the same since the intervals are equal: ΔT = 1 K = 1 °C. The thermal resistance of materials is of great interest to electronic engineers because most electrical components generate heat and need to be cooled.
The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.
Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...
In-situ thermal insulation measurement according to ASTM C0141, applying a heat flux sensor to a boiler wall On-site heat flux measurements are often focused on testing the thermal transport properties of for example pipes, tanks, ovens and boilers, by calculating the heat flux q or the apparent thermal conductivity λ {\displaystyle \lambda } .
The basic unit of insulation coefficient is the R SI, (1 m 2 ⋅K/W). 1 tog = 0.1 R SI. There is also a US clothing unit, the clo , equivalent to 0.155 R SI or 1.55 tog, described in ASTM D-1518. [ 7 ]