A typical motor start capacitor. A motor capacitor [1] [2] is an electrical capacitor that alters the current to one or more windings of a single-phase alternating-current induction motor to create a rotating magnetic field. [citation needed] There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run ...
Short title: Capasitor-start single-phase motor circuit diagram: Image title: A circuit diagram of a motor with LC circuit with capacitor embedded. Source: Energy-Efficient Electric Motors, Revised and Expanded, Ali Emadi, October 3, 2018, ISBN: 9781351836678
Schematic of a capacitor start motor. A capacitor start motor is a split-phase induction motor with a starting motor capacitor inserted in series with the startup winding, creating an LC circuit which produces a greater phase shift (and so, a much greater starting torque) than both split-phase and shaded pole motors. This motor has a ...
The capacitor-run designs keep the second winding on when running, improving torque. A resistance start design uses a starter inserted in series with the startup winding, creating reactance. Self-starting polyphase induction motors produce torque even at standstill.
A variation of the centrifugal switch used a changeover contact to ensure that the auxiliary windings remain in the circuit through a running capacitor. These motors are called two-value or capacitor start capacitor run motors. Centrifugal switches are found in many clothes dryers, supplying power to the motor in parallel with the start switch ...
Capacitor-run induction motors have a permanently connected phase-shifting capacitor in series with a second winding. The motor is much like a two-phase induction motor. Motor-starting capacitors are typically non-polarized electrolytic types, while running capacitors are conventional paper or plastic film dielectric types.
Even by the standards of shaded pole motors, the power output of these motors is usually very low. Because there is often no explicit starting mechanism, the rotor of a motor operating from a constant frequency mains supply must be very light so that it is capable of reaching running speed within one cycle of the mains frequency.
A single-phase supply connected to an alternating current electric motor does not produce a rotating magnetic field; single-phase motors need additional circuits for starting (capacitor start motor), and such motors are uncommon above 10 kW in rating.