enow.com Web Search

  1. Ads

    related to: central heating won't turn off air cleaner and pump with water control

Search results

  1. Results from the WOW.Com Content Network
  2. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    An automatic bleeding valve or air release valve (ARV) is a plumbing valve used to automatically release trapped air from a heating system. Air, or other gas, may collect within plumbing. For water delivery systems to taps and basins, particularly with good main supply pressure, this air is usually flushed through with the water flow and does ...

  3. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    Electric heating can either be purely resistance-type heating or make use of a heat pump system to take advantage of low-grade heat in the air or ground. A district heating system uses centrally located boilers or water heaters and circulates heat energy to individual customers by circulating hot water or steam.

  4. Thermostatic mixing valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_mixing_valve

    There are three main categories for water temperature controlling devices: Heat Source, Group Control, and Point-of-Use. Heat Source. These are used with central heating systems that use water as a medium. Tempering valves for use on hot water heat distribution systems; High flow rates suitable for use in under floor (radiant) heating applications

  5. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...

  6. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and climate control - for example, in the case of ...

  7. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...

  8. Air lock - Wikipedia

    en.wikipedia.org/wiki/Air_lock

    Air lock problems often occur when one is trying to recommission a system after it has been deliberately (for servicing) or accidentally emptied. Take, for example, a central heating system using a circulating pump to pump water through radiators. When filling such a system, air is trapped in the radiators. This air has to be vented using screw ...

  9. Control loop - Wikipedia

    en.wikipedia.org/wiki/Control_loop

    The control action is the switching on or off of the boiler. The process variable is the building temperature. This controller operates the heating system for a constant time regardless of the temperature of the building. In a closed-loop control system, the control action from the controller is dependent on the desired and actual process variable.

  1. Ads

    related to: central heating won't turn off air cleaner and pump with water control
  1. Related searches central heating won't turn off air cleaner and pump with water control

    central heating won't turn off air cleaner and pump with water control valve