enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Multipoint ground - Wikipedia

    en.wikipedia.org/wiki/Multipoint_ground

    A multipoint ground is an alternate type of electrical installation that attempts to solve the ground loop and mains hum problem by creating many alternate paths for electrical energy to find its way back to ground. The distinguishing characteristic of a multipoint ground is the use of many interconnected grounding conductors into a loose grid ...

  3. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The ground potential at different outlets may differ by as much as 10 to 20 volts [4] due to voltage drops from these currents. The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel.

  4. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    The "protective earth" (PE) safety ground wires in AC utility building wiring were not designed for, and cannot be used as an adequate substitute for an RF ground. The long utility ground wires have high impedance at certain frequencies. In the case of a transmitter, the RF current flowing through the ground wires can radiate radio frequency ...

  5. Reflections of signals on conducting lines - Wikipedia

    en.wikipedia.org/wiki/Reflections_of_signals_on...

    A time-domain reflectometer; an instrument used to locate the position of faults on lines from the time taken for a reflected wave to return from the discontinuity.. A signal travelling along an electrical transmission line will be partly, or wholly, reflected back in the opposite direction when the travelling signal encounters a discontinuity in the characteristic impedance of the line, or if ...

  6. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only ...

  7. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A hunk of copper is visible that is designed to be easily connected or disconnected from its place between two screws, rated for 600 A (as stamped on it). We also see the thick wires in standard colors (two yellow/green ground and two blue neutral), as well as markings PEN (protected earth and neutral), PE (protective earth) and N (neutral).

  8. Ground lift - Wikipedia

    en.wikipedia.org/wiki/Ground_lift

    Removal of the safety ground connection on equipment can expose users to an increased danger of electric shock and may contradict wiring regulations. [1] The safety ground is disconnected by an adaptor (cheater plug) in a power lead in which the ground conductor is deliberately disconnected, or by cutting a ground pin in the power plug. If a ...

  9. Lead (electronics) - Wikipedia

    en.wikipedia.org/wiki/Lead_(electronics)

    The lead wire is a coated copper wire, a tinned copper wire or another electrically conductive wire used to connect two locations electrically. In electronics, a lead (/ ˈ l iː d /) or pin is an electrical connector consisting of a length of wire or a metal pad (surface-mount technology) that is designed to connect two locations electrically.