The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD).
In order to reduce capital cost, in practice a minimum temperature difference (Δ T) at the pinch point is demanded, e.g., 10 °F. It is possible to estimate the heat exchanger area and capital cost, and hence the optimal Δ T minimum value. However, the cost curve is quite flat and the optimum may be affected by "topology traps".
Assume heat transfer [2] is occurring in a heat exchanger along an axis z, from generic coordinate A to B, between two fluids, identified as 1 and 2, whose temperatures along z are T 1 (z) and T 2 (z). The local exchanged heat flux at z is proportional to the temperature difference:
Tubular heat exchanger Partial view into inlet plenum of shell and tube heat exchanger of a refrigerant based chiller for providing air-conditioning to a building. A heat exchanger is a system used to transfer heat between a source and a working fluid. Heat exchangers are used in both cooling and heating processes. [1]
Types of recuperator, or cross plate heat exchanger. A recuperator is a special purpose counter-flow energy recovery heat exchanger positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, in order to recover the waste heat. Generally, they are used to extract heat from ...
When the purchase price of all the pumps, heat exchangers, pressure vessels, and other process equipment are multiplied by 5.0, a rough estimate of the total installed cost of the plant, including equipment, materials, construction, and engineering will be achieved. The accuracy of this estimate method usually is +/- 35%.
A thin external shell is affixed to the vessel shell with spot welds located in a regular pattern, often about 50 mm on center both horizontally and vertically. These so-called dimples impart turbulence to the heating or cooling media as it flows through the jacket (see Pillow plate heat exchanger). Plate Coils. Often very similar to dimple ...
A plate heat exchanger is a type of heat exchanger that uses metal plates to transfer heat between two fluids.This has a major advantage over a conventional heat exchanger in that the fluids are exposed to a much larger surface area because the fluids are spread out over the plates.