Search results
Results from the WOW.Com Content Network
In viral marketing, the K-factor can be used to describe the growth rate of websites, apps, or a customer base. The formula is roughly as follows: [ 1 ] i = number of invites sent by each customer {\displaystyle i={\text{number of invites sent by each customer }}} (e.g. if each new customer invites five friends, i = 5)
The K-factor is the bending capacity of sheet metal, and by extension the forumulae used to calculate this. [1] [2] [3] Mathematically it is an engineering aspect of geometry. [4] Such is its intricacy in precision sheet metal bending [5] (with press brakes in particular) that its proper application in engineering has been termed an art. [4] [5]
In transportation engineering, the K factor is defined as the proportion of annual average daily traffic occurring in an hour. [1] This factor is used for designing and analyzing the flow of traffic on highways. K factors must be calculated at a continuous count station, usually an "automatic traffic recorder", for a year before being determined.
K-factor (Elo rating system), a constant used in Elo rating system; K-factor (marketing), the growth rate of websites, apps, or a customer base; K-factor (sheet metal), the ratio of location of the neutral line to the material thickness; The K Factor, a fictional TV show within Harry Hill's TV Burp; Bondi k-factor, the "k" in Bondi k-calculus
The K factor or characterization factor is defined from Rankine boiling temperature °R=1.8Tb[k] and relative to water density ρ at 60°F: . K(UOP) = / The K factor is a systematic way of classifying a crude oil according to its paraffinic, naphthenic, intermediate or aromatic nature. 12.5 or higher indicate a crude oil of predominantly paraffinic constituents, while 10 or lower indicate a ...
K-distribution arises as the consequence of a statistical or probabilistic model used in synthetic-aperture radar (SAR) imagery. The K-distribution is formed by compounding two separate probability distributions, one representing the radar cross-section, and the other representing speckle that is a characteristic of coherent imaging. It is also ...
In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.
Pressure and temperature sensors providing pulses can be used to determine mass flow, with division of the pulses by the K-factor, or multiplication with the inverse of the K-factor providing factored totalization, and rate indication. Furthermore, by dividing the pulse rate by the K-Factor, the volumetric throughput per unit time of the rate ...