Search results
Results from the WOW.Com Content Network
No panel rotation is being considered. Panel Volume: V = w x h x d = 6.0 m x 3.0 m x 0.15 m = 2.7 m 3; Weight: W = V x concrete specific gravity = 2.7 m 3 x 24 kN/m 3 = 64.8 kN; Calculated casting bed suction Suction area: A = w x h = 6.0 m x 3.0 m = 18 m 2; Assuming 1.0 kN/m 2 is applied for oiled steel formwork
Extra heavy concrete sleepers [10] 87.8 m (288 ft 11 ⁄ 16 in) North American rail network: 1,435 mm (4 ft 8 + 1 ⁄ 2 in) Absolute minimum radius; not on lines for general service 85 m (279 ft) Windberg Railway (de:Windbergbahn) 1,435 mm (4 ft 8 + 1 ⁄ 2 in) (between Freital-Birkigt and Dresden-Gittersee) - restrictions to wheelbase 80 m ...
Lift slab construction (also called the Youtz-Slick Method) is a method of constructing concrete buildings by casting the floor or roof slab on top of the previous slab and then raising (jacking) the slab up with hydraulic jacks. This method of construction allows for a large portion of the work to be completed at ground level, negating the ...
Headway is the distance or duration between vehicles in a transit system. The minimum headway is the shortest such distance or time achievable by a system without a reduction in the speed of vehicles. The precise definition varies depending on the application, but it is most commonly measured as the distance from the tip (front end) of one ...
The overall thickness of sandwich wall panels in commercial applications is typically 8 inches, but their designs are often customized to the application. In a typical 8-inch wall panel the concrete wythes are each 2-3/8 inches thick), sandwiching 3-1/4 inches of high R-value insulating foam. The interior and exterior wythes of concrete are ...
Brand new Hanseatic-themed WBS 70 panel buildings in Rostock-Stadtmitte (September 1986) In East Germany, large panel system-building areas have been designated as Neubaugebiet ("New development area"). Virtually all new residential buildings since the 1960s were built in this style, as it was a quick and relatively inexpensive way to curb the ...
The precast concrete slab has tubular voids extending the full length of the slab, typically with a diameter equal to the 2/3–3/4 the thickness of the slab. This makes the slab much lighter than a massive solid concrete floor slab of equal thickness or strength. The reduced weight also lowers material and transportation costs.
A finished tilt-up building. Tilt-up, tilt-slab or tilt-wall is a type of building and a construction technique using concrete.Though it is a cost-effective technique with a shorter completion time, [1] poor performance in earthquakes has mandated significant seismic retrofit requirements in older buildings.