enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Comprehensive two-dimensional gas chromatography - Wikipedia

    en.wikipedia.org/wiki/Comprehensive_two...

    Comprehensive two-dimensional gas chromatography, or GC×GC, is a multidimensional gas chromatography technique that was originally described in 1984 by J. Calvin Giddings [1] and first successfully implemented in 1991 by John Phillips and his student Zaiyou Liu. [2] GC×GC utilizes two different columns with two different stationary phases. In ...

  3. Gas chromatography - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography

    Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]

  4. Electron capture detector - Wikipedia

    en.wikipedia.org/wiki/Electron_capture_detector

    The answer is recombination of negative ions or electrons with the positive ions of the makeup gas before these charged entities can be collected at anode and cathode respectively. Negative and positive ions recombine much more rapidly than electrons and positive ions; it is this more rapid neutralization that is the origin of the observed ...

  5. Flame ionization detector - Wikipedia

    en.wikipedia.org/wiki/Flame_ionization_detector

    The design of the flame ionization detector varies from manufacturer to manufacturer, but the principles are the same. Most commonly, the FID is attached to a gas chromatography system. The eluent exits the gas chromatography column (A) and enters the FID detector’s oven (B). The oven is needed to make sure that as soon as the eluent exits ...

  6. Kovats retention index - Wikipedia

    en.wikipedia.org/wiki/Kovats_retention_index

    If column dimensions Length×diameter×film are divided by 2 and gas velocity is doubled by using H2 in place of Helium, the hold times must be divided by 4 and the ramps must be multiplied by 4 to keep the same index and the same retention temperature for the same compound analyzed. Method translation rules are incorporated in some ...

  7. Thermal conductivity detector - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_detector

    The thermal conductivity detector (TCD), also known as a katharometer, is a bulk property detector and a chemical specific detector commonly used in gas chromatography. [1] This detector senses changes in the thermal conductivity of the column eluent and compares it to a reference flow of carrier gas. Since most compounds have a thermal ...

  8. Atmospheric-pressure chemical ionization - Wikipedia

    en.wikipedia.org/wiki/Atmospheric-pressure...

    Atmospheric pressure chemical ionization chamber cross section. Atmospheric pressure chemical ionization (APCI) is an ionization method used in mass spectrometry which utilizes gas-phase ion-molecule reactions at atmospheric pressure (10 5 Pa), [1] [2] commonly coupled with high-performance liquid chromatography (HPLC). [3]

  9. Two-dimensional chromatography - Wikipedia

    en.wikipedia.org/wiki/Two-dimensional_chromatography

    Gas chromatography-mass spectrometry (GC-MS) is a two-dimensional chromatography technique that combines the separation technique of gas chromatography with the identification technique of mass spectrometry. GC-MS is the single most important analytical tool for the analysis of volatile and semi-volatile organic compounds in complex mixtures. [7]