Search results
Results from the WOW.Com Content Network
Heat capacity, c p? J/(mol K) Liquid properties Std enthalpy change of formation, Δ f H o liquid: −687.0 kJ/mol Std Gibbs free energy of formation, Δ f G o liquid: −619.8 kJ/mol Standard molar entropy, S o liquid: 239.7 J/(mol K) Heat capacity, c p: 145. J/(mol K) Gas properties Std enthalpy change of formation, Δ f H o gas: −657. kJ ...
Furthermore, the parallel use of three precursor ions may allow the operator to distinguish between two or more compounds that react to produce ions of the same mass-to-charge ratio in certain spectra. For example, dimethyl sulfide (C 2 H 6 S, 62 amu) accepts a proton when it reacts with H 3 O + to generate C 2 H 7 S + product ions which appear ...
The results are presented as a mass spectrum, a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used in many different fields and is applied to pure samples as well as complex mixtures. A mass spectrum is a type of plot of the ion signal as a function of the mass-to-charge ratio.
A mass chromatogram is a representation of mass spectrometry data as a chromatogram, where the x-axis represents time and the y-axis represents signal intensity. [1] The source data contains mass information; however, it is not graphically represented in a mass chromatogram in favor of visualizing signal intensity versus time.
Mass spectral interpretation is the method employed to identify the chemical formula, characteristic fragment patterns and possible fragment ions from the mass spectra. [1] [2] Mass spectra is a plot of relative abundance against mass-to-charge ratio. It is commonly used for the identification of organic compounds from electron ionization mass ...
Electron ionization mass spectrum of toluene. Note parent peak corresponding to molecular mass M = 92 (C 7 H 8 +) and highest peak at M-1 = 91 (C 7 H 7 +, quasi-stable tropylium cation). A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass ...
Atmospheric pressure chemical ionization chamber cross section. Atmospheric pressure chemical ionization (APCI) is an ionization method used in mass spectrometry which utilizes gas-phase ion-molecule reactions at atmospheric pressure (10 5 Pa), [1] [2] commonly coupled with high-performance liquid chromatography (HPLC). [3]
The DART ion source is a kind of gas-phase ionization, and it requires some sort of volatility of the analyte to support thermally assisted desorption of analyte ions. [14] This limits the size range of the molecules that can be analyzed by DART i.e. m/z 50 to 1200. [1] [15] DART-MS is capable of semi-quantitative and quantitative analysis. To ...