enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Closed-loop transfer function - Wikipedia

    en.wikipedia.org/wiki/Closed-loop_transfer_function

    An example of a closed-loop block diagram, from which a transfer function may be computed, is shown below: The summing node and the G(s) and H(s) blocks can all be combined into one block, which would have the following transfer function: () = + ()

  3. File:Bode plot template.pdf - Wikipedia

    en.wikipedia.org/wiki/File:Bode_plot_template.pdf

    # set terminal svg enhanced size 875 1250 fname "Times" fsize 25 set terminal postscript enhanced portrait dashed lw 1 "Helvetica" 14 set output "bode.ps" # ugly part of something G(w,n) = 0 * w * n + 100000 # 1 / (sqrt(1 + w**(2*n))) dB(x) = 0 + x + 100000 # 20 * log10(abs(x)) P(w) = w * 0 + 200 # -atan(w)*180/pi # Gridlines set grid # Set x axis to logarithmic scale set logscale x 10 set ...

  4. Boole's rule - Wikipedia

    en.wikipedia.org/wiki/Boole's_rule

    Example implementation in Common Lisp ( defun integrate-composite-booles-rule ( f a b n ) "Calculates the composite Boole's rule numerical integral of the function F in the closed interval extending from inclusive A to inclusive B across N subintervals."

  5. Root locus analysis - Wikipedia

    en.wikipedia.org/wiki/Root_locus_analysis

    The following Python code can also be used to calculate and plot the root locus of the closed-loop transfer function using the Python Control Systems Library [14] and Matplotlib [15]. import control as ct import matplotlib.pyplot as plt # Define the transfer function sys = ct .

  6. Bode plot - Wikipedia

    en.wikipedia.org/wiki/Bode_plot

    It is usually a combination of a Bode magnitude plot, expressing the magnitude (usually in decibels) of the frequency response, and a Bode phase plot, expressing the phase shift. As originally conceived by Hendrik Wade Bode in the 1930s, the plot is an asymptotic approximation of the frequency response, using straight line segments. [1]

  7. Sensitivity (control systems) - Wikipedia

    en.wikipedia.org/wiki/Sensitivity_(control_systems)

    A basic closed loop control system, using unity negative feedback. C(s) and G(s) denote compensator and plant transfer functions, respectively. Let () and () denote the plant and controller's transfer function in a basic closed loop control system written in the Laplace domain using unity negative feedback.

  8. Step response - Wikipedia

    en.wikipedia.org/wiki/Step_response

    Figure 5 is the Bode gain plot for the two-pole amplifier in the range of frequencies up to the second pole position. The assumption behind Figure 5 is that the frequency f 0 dB lies between the lowest pole at f 1 = 1/(2πτ 1) and the second pole at f 2 = 1/(2πτ 2). As indicated in Figure 5, this condition is satisfied for values of α ≥ 1.

  9. Nichols plot - Wikipedia

    en.wikipedia.org/wiki/Nichols_plot

    A Nichols plot. The Nichols plot is a plot used in signal processing and control design, named after American engineer Nathaniel B. Nichols. [1] [2] [3] It plots the phase response versus the response magnitude of a transfer function for any given frequency, and as such is useful in characterizing a system's frequency response.