enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    The section sets provisions for increasing the upper air temperature limit at elevated air speeds above 0.20 m/s (39 ft/min). The methodology is based on the SET (Standard Effective Temperature) model, which provides a way to assign an effective temperature (at a standard metabolic rate, and clothing insulation values) to compare thermal ...

  4. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    The above equation only takes into account the temperature differences and ignores two important parameters, being 1) solar radiative flux; and 2) infrared exchanges from the sky. The concept of T sol-air was thus introduced to enable these parameters to be included within an improved calculation. The following formula results:

  5. Thermal comfort - Wikipedia

    en.wikipedia.org/wiki/Thermal_comfort

    ASHRAE 55-2017 defines the Cooling Effect (CE) at elevated air speed (above 0.2 metres per second (0.66 ft/s)) as the value that, when subtracted from both the air temperature and the mean radiant temperature, yields the same SET value under still air (0.1 m/s) as in the first SET calculation under elevated air speed.

  6. Thermal destratification - Wikipedia

    en.wikipedia.org/wiki/Thermal_destratification

    Because axial destratification fans can achieve destratification with low CFMs, it is imperative that the air leaving the nozzle achieve an air speed at the floor of between 0.2 and 0.5 m/s. The result of this level of air movement is the integration of conditioned air from the ceiling with air at the floor level.

  7. Wet-bulb globe temperature - Wikipedia

    en.wikipedia.org/wiki/Wet-bulb_globe_temperature

    The wet-bulb globe temperature (WBGT) is a measure of environmental heat as it affects humans. Unlike a simple temperature measurement, WBGT accounts for all four major environmental heat factors: air temperature, humidity, radiant heat (from sunlight or sources such as furnaces), and air movement (wind or ventilation). [ 1 ]

  8. Qalculate! - Wikipedia

    en.wikipedia.org/wiki/Qalculate!

    Qalculate! supports common mathematical functions and operations, multiple bases, autocompletion, complex numbers, infinite numbers, arrays and matrices, variables, mathematical and physical constants, user-defined functions, symbolic derivation and integration, solving of equations involving unknowns, uncertainty propagation using interval arithmetic, plotting using Gnuplot, unit and currency ...

  9. Operative temperature - Wikipedia

    en.wikipedia.org/wiki/Operative_temperature

    Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...