Search results

  1. Results from the WOW.Com Content Network
  2. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...

  3. File:ECG limb and chest electrodes placement.png - Wikipedia

    en.wikipedia.org/wiki/File:ECG_limb_and_chest...

    You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.

  4. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    In a 12-lead ECG, all leads except the limb leads are assumed to be unipolar (aVR, aVL, aVF, V 1, V 2, V 3, V 4, V 5, and V 6). The measurement of a voltage requires two contacts and so, electrically, the unipolar leads are measured from the common lead (negative) and the unipolar lead (positive).

  5. Sinus rhythm - Wikipedia

    en.wikipedia.org/wiki/Sinus_rhythm

    any of biphasic (–/+), positive or negative in lead aVL; positive in all chest leads, except for V1 which may be biphasic (+/–) [2] If the P waves do not meet these criteria, they must be originating from an abnormal site elsewhere in the atria and not from the sinus node; the ECG cannot, therefore, be classed as showing a sinus rhythm. [2]

  6. File:ECG paper 12 leads.svg - Wikipedia

    en.wikipedia.org/wiki/File:ECG_paper_12_leads.svg

    You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.

  7. Electrocardiography in myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography_in...

    The use of additional ECG leads like right-sided leads V3R and V4R and posterior leads V7, V8, and V9 may improve sensitivity for right ventricular and posterior myocardial infarction. In spite of these limitations, the 12 lead ECG stands at the center of risk stratification for the patient with suspected acute myocardial infarction.

  8. Holter monitor - Wikipedia

    en.wikipedia.org/wiki/Holter_monitor

    Each Holter system has hardware (called monitor or recorder) for recording the signal, and software for review and analysis of the record. There may be a "patient button" on the front that the patient can press at specific instants such as feeling/being sick, going to bed, taking pills, marking an event of symptoms which is then documented in the symptoms diary, etc.; this records a mark that ...

  9. Sgarbossa's criteria - Wikipedia

    en.wikipedia.org/wiki/Sgarbossa's_criteria

    Several other studies have evaluated the usefulness of different ECG findings in diagnosing MI when LBBB is present. Smith et al. modified Sgarbossa's original criteria. [6] Smith modified Sgarbossa rule: at least one lead with concordant STE (Sgarbossa criterion 1) or; at least one lead of V1-V3 with concordant ST depression (Sgarbossa ...