Search results
Results from the WOW.Com Content Network
The line is modeled by a series of differential segments with differential series elements ( , ) and shunt elements ( , ) (as shown in the figure at the beginning of the article). The characteristic impedance is defined as the ratio of the input voltage to the input current of a semi-infinite length of line.
The Shunt equation (also known as the Berggren equation) quantifies the extent to which venous blood bypasses oxygenation in the capillaries of the lung. “Shunt” and “ dead space “ are terms used to describe conditions where either blood flow or ventilation do not interact with each other in the lung, as they should for efficient gas ...
Power transmission lines. Electric power transmission is the bulk movement of electrical energy from a generating site, such as a power plant, to an electrical substation and is different from the local wiring between high-voltage substations and customers, which is typically referred to as electric power distribution.
Common-mode choke with two 20 mH windings, rated to handle 2 amperes. In electronics, a choke is an inductor used to block higher-frequency alternating currents (AC) while passing direct current (DC) and lower-frequency ACs in a circuit.
In its most generalized form, a three-phase CSI employs the same conduction sequence as a six-pulse rectifier. At any time, only one common-cathode switch and one common-anode switch are on. [18] As a result, line currents take discrete values of –ii, 0 and ii. States are chosen such that a desired waveform is output and only valid states are ...
In the voltage regulation formula, V no load is the voltage measured at the receiving end terminals when the receiving end is an open circuit. The entire short line model is an open circuit in this condition, and no current flows in an open circuit, so I = 0 A and the voltage drop across the line given by Ohm’s law V line drop = IZ line is 0 V.
A shunt reactor is typically connected to an end of a long transmission line or a weak system to prevent overvoltage under light load (Ferranti effect); [10] passive sources of reactive power (e. g., shunt or series capacitors). shunt capacitors are used in power systems since the 1910s and are popular due to low cost and relative ease of ...
The reason for this is that the shunt element has more capacitance than is required by the transform so some is still left over after applying the transform. If the excess were instead, in the element nearest the transformer, this could be dealt with by first shifting the excess to the other side of the transformer before carrying out the ...