The reduction length is usually equal to the average of the larger and smaller pipe diameters. Although reducers are usually concentric, eccentric reducers are used as needed to maintain the top- or bottom-of-pipe level. A reducer can also be used either as a nozzle or diffuser, depending on the mach number of the flow. [citation needed]
A copper concentric reducer. A concentric reducer is used to join pipe sections or tube sections on the same axis. [1] The concentric reducer is cone-shaped, and is used when there is a shift in diameter between pipes. [1] For example, when a 1" pipe transitions into a 3/4" pipe and the top or bottom of the pipe doesn't need to remain level. [2]
A compression fitting 15 mm isolating valve. A compression fitting is a fitting used in plumbing and electrical conduit systems to join two tubes or thin-walled pipes together. . In instances where two pipes made of dissimilar materials are to be joined (most commonly PVC and copper), the fittings will be made of one or more compatible materials appropriate for the connect
Eccentric reducers are used at the suction side of pumps to ensure air does not accumulate in the pipe. The gradual accumulation of air in a concentric reducer could result in a large bubble that could eventually cause the pump to stall or cause cavitation when drawn into the pump. Eccentric reducers exhibit a unique design with one side having ...
Pipe sizes can be confusing because the terminology may relate to historical dimensions. For example, a half-inch iron pipe does not have any dimension that is a half inch. Initially, a half inch pipe did have an inner diameter of 1 ⁄ 2 inch (13 mm)—but it also had thick walls. As technology improved, thinner walls became possible, but the ...
These sizing schemes allow for universal adaptation of transitional fittings. For instance, 1/2" PeX tubing is the same size as 1/2" copper tubing. 1/2" PVC on the other hand is not the same size as 1/2" tubing, and therefore requires either a threaded male or female adapter to connect them.
A tube and pipe may be specified by standard pipe size designations, e.g., nominal pipe size, or by nominal outside or inside diameter and/or wall thickness. The actual dimensions of pipe are usually not the nominal dimensions: A 1-inch pipe will not actually measure 1 inch in either outside or inside diameter, whereas many types of tubing are ...
The iron pipe size standard came into being early in the 19th century and remained in effect until after World War II. The IPS system was primarily used in the United States and the United Kingdom. In the 1920s, the Copper Tube Size (CTS) standard was combined with the IPS standard.