Search results
Results from the WOW.Com Content Network
A virtual controller can be added and tuned to give desired overall system response. Graphical control element such as sliders and buttons allow control of what-if analysis for operator training or controller tuning. Although VisSim was originally designed for use by control engineers, it can be used for any type of mathematical model.
VisSim - system simulation and optional C-code generation of electrical, process, control, bio-medical, mechanical and UML State chart systems. Vortex (software) - a complete simulation platform featuring a realtime physics engine for rigid body dynamics, an image generator, desktop tools (Editor and Player) and more. Also available as Vortex ...
Departure of such a variable from its setpoint is one basis for error-controlled regulation using negative feedback for automatic control. [3] A setpoint can be any physical quantity or parameter that a control system seeks to regulate, such as temperature, pressure, flow rate, position, speed, or any other measurable attribute.
Block diagram of a control system with disturbance. The sensitivity function also describes the transfer function from external disturbance to process output. In fact, assuming an additive disturbance n after the output of the plant, the transfer functions of the closed loop system are given by
A block diagram is a diagram of a system in which the principal parts or functions are represented by blocks connected by lines that show the relationships of the blocks. [1] They are heavily used in engineering in hardware design , electronic design , software design , and process flow diagrams .
A control system manages, commands, directs, or regulates the behavior of other devices or systems using control loops. It can range from a single home heating controller using a thermostat controlling a domestic boiler to large industrial control systems which are used for controlling processes or machines.
An example of a closed-loop block diagram, from which a transfer function may be computed, is shown below: The summing node and the G(s) and H(s) blocks can all be combined into one block, which would have the following transfer function: () = + ()
Engineers run simulations with this system-level model to verify performance against requirements and to optimize tunable parameters. System-level simulation is used to test controllers connected to the simulated system instead of the real one. If the controller is a hardware controller like an ECU, the method is called hardware-in-the-loop. If ...