enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Radiation treatment planning - Wikipedia

    en.wikipedia.org/wiki/Radiation_treatment_planning

    The information from a prior CT scan of the patient allows more accurate modelling of the behaviour of the radiation as it travels through the patient's tissues. Different dose calculation models are available, including pencil beam , convolution-superposition and monte carlo simulation , with precision versus computation time being the ...

  3. Image-guided radiation therapy - Wikipedia

    en.wikipedia.org/wiki/Image-guided_radiation_therapy

    Other radiation therapy machines which incorporate real-time MRI tracking of tumors are currently in development. MRI-guided radiation therapy enables clinicians to see a patient's internal anatomy in real-time using continual soft-tissue imaging and allows them to keep the radiation beams on target when the tumour moves during treatment. [14]

  4. CT scan - Wikipedia

    en.wikipedia.org/wiki/CT_scan

    The risks of CT scan radiation are especially important in patients undergoing recurrent CT scans within a short time span of one to five years. [ 157 ] [ 158 ] [ 159 ] Some experts note that CT scans are known to be "overused," and "there is distressingly little evidence of better health outcomes associated with the current high rate of scans."

  5. 4DCT - Wikipedia

    en.wikipedia.org/wiki/4DCT

    Most radiation therapy is planned using the results of a 3D CT scan. A 3D scan largely presents a snapshot of the body at a particular point in time, however due to the time of the acquisition, in which the patient is likely to have moved in some way (even if only breathing), there will be an element of blurring or averaging in the 3D scan. [ 6 ]

  6. Monte Carlo method for photon transport - Wikipedia

    en.wikipedia.org/wiki/Monte_Carlo_method_for...

    The goal of radiation therapy is to deliver energy, generally in the form of ionizing radiation, to cancerous tissue while sparing the surrounding normal tissue. Monte Carlo modeling is commonly employed in radiation therapy to determine the peripheral dose the patient will experience due to scattering, both from the patient tissue as well as scattering from collimation upstream in the linear ...

  7. Operation of computed tomography - Wikipedia

    en.wikipedia.org/wiki/Operation_of_computed...

    In conventional CT machines, an X-ray tube and detector are physically rotated behind a circular shroud (see the image above right). An alternative, short lived design, known as electron beam tomography (EBT), used electromagnetic deflection of an electron beam within a very large conical X-ray tube and a stationary array of detectors to achieve very high temporal resolution, for imaging of ...

  8. Radiation therapy - Wikipedia

    en.wikipedia.org/wiki/Radiation_therapy

    An enhancement of virtual simulation is 3-dimensional conformal radiation therapy (3DCRT), in which the profile of each radiation beam is shaped to fit the profile of the target from a beam's eye view (BEV) using a multileaf collimator (MLC) and a variable number of beams. When the treatment volume conforms to the shape of the tumor, the ...

  9. Lung cancer screening - Wikipedia

    en.wikipedia.org/wiki/Lung_cancer_screening

    The currently used low dose CT scan results in a radiation exposure of about 2 millisieverts (equal to roughly 20 two-view chest x-rays). [11] It has been estimated that radiation exposure from repeated screening studies could induce cancer formation in a small percentage of screened subjects, so this risk should be mitigated by a (relatively ...