The COP of absorption chillers can be improved by adding a second or third stage. Double and triple effect chillers are significantly more efficient than single effect chillers, and can surpass a COP of 1. They require higher pressure and higher temperature steam, but this is still a relatively small 10 pounds of steam per hour per ton of cooling.
Critical temperature in degrees Celsius; Absolute critical pressure in kilopascals; Since over 100,000 refrigerant blends are possible, [2] this list should only have notable refrigerants and refrigerant blends.
R-410A was invented and patented by Allied Signal (later Honeywell) in 1991. [5] Other producers around the world have been licensed to manufacture and sell R-410A. [6] R-410A was successfully commercialized in the air conditioning segment by a combined effort of Carrier Corporation, Emerson Climate Technologies, Inc., Copeland Scroll Compressors (a division of Emerson Electric Company), and ...
A refrigerant needs to have: a boiling point that is somewhat below the target temperature (although boiling point can be adjusted by adjusting the pressure appropriately), a high heat of vaporization, a moderate density in liquid form, a relatively high density in gaseous form (which can also be adjusted by setting pressure appropriately), and ...
The pressure on a pressure-temperature diagram (such as the water phase diagram shown above) is the partial pressure of the substance in question. A phase diagram in physical chemistry , engineering , mineralogy , and materials science is a type of chart used to show conditions (pressure, temperature, etc.) at which thermodynamically distinct ...
At the start of the thermodynamic cycle the refrigerant enters the compressor as a low pressure and low temperature vapor. In heat pumps, this refrigerant is typically R32 refrigerant or R290 refrigerant. Then the pressure is increased and the refrigerant leaves as a higher temperature and higher pressure superheated gas.
Unlike CFCs used as refrigerants, trifluoroethane has no chlorine atoms and therefore is not ozone-depleting. Its high chemical stability and infra-red absorbency make it a potent greenhouse gas with a lifetime of about 50 years and a global warming potential of 4300, which are at the high end compared to many other commonly used HFC refrigerants.
An enthalpy–entropy chart, also known as the H–S chart or Mollier diagram, plots the total heat against entropy, [1] describing the enthalpy of a thermodynamic system. [2] A typical chart covers a pressure range of 0.01–1000 bar , and temperatures up to 800 degrees Celsius . [ 3 ]