enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    The resistance of copper wire is approximately ⁠ 1 ohms / 1000 feet ⁠ for 10 AWG, ⁠ 10 ohms / 1000 feet ⁠ for 20 AWG, ⁠ 100 ohms / 1000 feet ⁠ for 30 AWG, and so on. [ 5 ] : 27 Because aluminum wire has a conductivity of approximately 61% of copper, an aluminum wire has nearly the same resistance as a copper wire that is two sizes ...

  3. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    A device for measuring American wire gauge. Wire gauge is a measurement of wire diameter. This determines the amount of electric current the wire can safely carry, as well as its electrical resistance and weight.

  4. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  5. Standard wire gauge - Wikipedia

    en.wikipedia.org/wiki/Standard_wire_gauge

    A table of the gauge numbers and wire diameters is shown below. [1] [2] The basis of the system is the thou (or mil in US English), or 0.001 in. Sizes are specified as wire diameters, stated in thou and tenths of a thou (mils and tenths). The wire diameter diminishes with increasing size number.

  6. Electrical resistivities of the elements (data page) - Wikipedia

    en.wikipedia.org/wiki/Electrical_resistivities_of...

    As quoted in an online version of: David R. Lide (ed), CRC Handbook of Chemistry and Physics, 84th Edition.CRC Press. Boca Raton, Florida, 2003; Section 4, Properties of the Elements and Inorganic Compounds; Physical Properties of the Rare Earth Metals

  7. Talk:American wire gauge - Wikipedia

    en.wikipedia.org/wiki/Talk:American_wire_gauge

    The table for approximate resistance is supposedly taken from page 27 of reference 6. But it does not agree with the table in that reference. Yes, the referenced table has the data spread across 3 columns for some reason (readability?), but by my reading, the reference table is a lot closer to the AWG wire sizes table than the table here.

  8. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  9. Litz wire - Wikipedia

    en.wikipedia.org/wiki/Litz_wire

    The resistance of a conductor depends on its cross-sectional area; a conductor with a larger area has a lower resistance for a given length. However at high frequencies, alternating current (AC) does not penetrate deeply into conductors due to eddy currents induced in the material; it tends to flow near the surface.