enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Trap primer - Wikipedia

    en.wikipedia.org/wiki/Trap_primer

    A trap primer (or trap seal primer) is a plumbing device or valve that adds water to traps.The water seals in traps are needed to prevent sewer gases from entering buildings, but because this water is exposed to the air, it is subject to evaporation over time in infrequently used floor drains, leading to the release of sewer gas into the environment.

  3. Plumbing drawing - Wikipedia

    en.wikipedia.org/wiki/Plumbing_drawing

    A plumbing drawing, a type of technical drawing, shows the system of piping for fresh water going into the building and waste going out, both solid and liquid. It also includes fuel gas drawings. Mainly plumbing drawing consist of water supply system drawings, drainage system drawings, irrigation system drawings, storm water system drawings. In ...

  4. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.

  5. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    Valves stop (or regulate) the flow of liquids or gases. They are categorized by application, such as isolation, throttling, and non-return. Isolation valves temporarily disconnect part of a piping system to allow maintenance or repair, for example. Isolation valves are typically left in either a fully open or closed position.

  6. Trap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Trap_(plumbing)

    Trap with copper drain pipe at underside of firestop packing in two-hour fire-resistance rated concrete floor slab Typical P-trap. Maintaining the water seal is critical to trap operation; traps might dry out, and poor venting can suction or blow water out of the traps. This is usually avoided by venting the drain pipes downstream of the trap ...

  7. Floor drain - Wikipedia

    en.wikipedia.org/wiki/Floor_drain

    Floor drain system in bathroom, Korea. A floor drain is a plumbing fixture that is installed in the floor of a structure, mainly designed to remove any standing water near it. They are usually round, but can also be square or rectangular. They usually range from 2 to 12 inches (5.1 to 30.5 cm); most are 4 inches (10 cm) in diameter.

  8. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become flooded. An example of where backflow would harm the water supply is the use of well washing devices inside underground sewerage pumping stations.

  9. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    Brass-bodied float valve. An automatic bleeding valve or air release valve (ARV) is a plumbing valve used to automatically release trapped air from a heating system. Air, or other gas, may collect within plumbing. For water delivery systems to taps and basins, particularly with good main supply pressure, this air is usually flushed through with ...