Search results
Results from the WOW.Com Content Network
Type I atrial flutter, counterclockwise rotation with 3:1 and 4:1 AV nodal block. Atrial flutter with a two to one block. Note the P waves hiding in the T waves in leads V1 and V2. Type I atrial flutter, also known as common atrial flutter or typical atrial flutter, has an atrial rate of 240 to 340 beats/minute.
Type 2 or atypical atrial flutter is where a re-entrant circuit develops in either the right or left atrium, but the exact location is less clearly defined. Again though we’ve got a similar setup where a wave of activated tissue, or depolarization hits a bit of tissue in such a way that it creates a loop of depolarization that keeps going ...
[1] [2] Ventricular tachycardia is a regular rhythm with a rate of 140-250 bpm, there are no P waves and the main feature is a wide QRS complex (0.12 and greater) Ventricular fibrillation has no p waves or QRS complexes, there are only wavy irregular deflections throughout the heart rhythm, at this point the heart would have a rate of 0 and be ...
A 12 lead ECG showing sinus tachycardia. Sinus tachycardia is usually apparent on an ECG, but if the heart rate is above 140 bpm the P wave may be difficult to distinguish from the previous T wave and one may confuse it with a paroxysmal supraventricular tachycardia or atrial flutter with a 2:1 block.
Junctional rhythm is seen equally in men and women, and can be seen intermittently in young children and athletes, especially during sleep. It occurs commonly in patients with sinus node dysfunction. 1/600 cardiology patients over the age of 65 have sinus node dysfunction. [1]
Second-degree atrioventricular block (AV block) is a disease of the electrical conduction system of the heart.It is a conduction block between the atria and ventricles.The presence of second-degree AV block is diagnosed when one or more (but not all) of the atrial impulses fail to conduct to the ventricles due to impaired conduction.
Electrode placement for Lewis lead; RL electrode (green), not shown, remains on leg . A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG.
Multifocal atrial tachycardia is characterized by an electrocardiogram (ECG) strip with three or more discrete P wave morphologies in the same lead, not including that originating from the sinoatrial node, plus tachycardia, which is a heart rate exceeding 100 beats per minute (although some suggest using a threshold of 90 beats per minute ...