Search results
Results from the WOW.Com Content Network
The combustion chamber was connected to the compressor outlet by a very large single spiral duct giving the engine an asymmetrical appearance. Whittle designed the centrifugal compressor to develop about 4:1 pressure ratio when, as far as he was aware, the best previously demonstrated performance in a single stage was about 2.5:1.
A common source of unintentional backfeeding is an electrical generator (typically a portable generator) that is improperly connected to a building electrical system.A properly installed electrical generator incorporates the use of a transfer switch or generator interlock kit to ensure the incoming electrical service line is disconnected when the generator is providing power to the building.
A quick supplemental screening test for these simple miswiring errors can be performed using a non-contact voltage tester (NCVT) or non-contact voltage detector. [4] If a problem is thus identified, it can be investigated further using more-advanced equipment, or the outlet in question can be de-energized and disassembled for careful scrutiny. [4]
Further gas flow in the case of pressure shocks. The entry of air or oxygen into the distribution line or single cylinders. Flashbacks which are the rapid propagation of a flame down the hose. Further gas flow in the event of a burnback. According to the standard DIN EN ISO 5175-1 (formerly EN 730-1) they include a minimum of two safety elements:
Back siphonage is not to be confused with backflow; which is the reversed flow of water from the outlet end to the supply end caused by pressure occurring at the outlet end. [51] Also, building codes usually demand a check valve where the water supply enters a building to prevent backflow into the drinking water system.
As well as detecting a blocked supply of oxygen, these must also detect a blocked exhaust or reversed flow in the exhaust flue owing to wind conditions. Two methods are used to provide these, an Oxygen Depletion System (ODS) that measures the availability of oxygen for combustion or an Atmospheric Sensing Device (ASD) measures excess heat rise ...
The engine's design is unusual; the core flow path is reversed twice. Aft of the fan, the axial compressor has five stages, after which the gas path progresses to the aft end of the engine. There, it is reversed to flow through a centrifugal compressor stage, the combustors and then the turbine stages.
Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.