To express the efficiency of a generator or power plant as a percentage, invert the value if dimensionless notation or same unit are used. For example: A heat rate value of 5 gives an efficiency factor of 20%. A heat rate value of 2 kWh/kWh gives an efficiency factor of 50%. A heat rate value of 4 MJ/MJ gives an efficiency factor of 25%.
For fossil fuels the free enthalpy of reaction is usually only slightly less than the enthalpy of reaction so from equations and we can see that the energy efficiency will be correspondingly larger than the energy law efficiency. For example, a typical combined cycle power plant burning methane may have an energy efficiency of 55%, while its ...
The theoretical-maximum efficacy at that wavelength is 525 lm/w, so the lamp has a luminous efficiency of 38.1%. Because the lamp is monochromatic, the luminous efficiency nearly matches the wall-plug efficiency of < 40%. [7] [8] Calculations for luminous efficiency become more complex for lamps that produce white light or a mixture of spectral ...
If energy output and input are expressed in the same units, efficiency is a dimensionless number. [1] Where it is not customary or convenient to represent input and output energy in the same units, efficiency-like quantities have units associated with them. For example, the heat rate of a fossil fuel power plant may be expressed in BTU per ...
The central concept of the Lawson criterion is an examination of the energy balance for any fusion power plant using a hot plasma. This is shown below: Net power = Efficiency × (Fusion − Radiation loss − Conduction loss) Net power is the excess power beyond that needed internally for the process to proceed in any fusion power plant.
In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...
If a plant is only needed during the day, for example, even if it operates at full power output from 8 am to 8 pm every day (12 hours) all year long, it would only have a 50% capacity factor. Due to low capacity factors, electricity from peaking power plants is relatively expensive because the limited generation has to cover the plant fixed costs.
In reality, each gas-fired plant has a different fuel efficiency, but 49.13% is used as a standard in the UK market because it provides an easy conversion between gas and power volumes. The spark spread value is therefore the power price minus the gas cost divided by 0.4913, i.e. Spark Spread = Power Price – (Gas cost/0.4913).