enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Volume correction factor - Wikipedia

    en.wikipedia.org/wiki/Volume_Correction_Factor

    That is, observed temperatures above 60 °F (or the base temperature used) typically correlate with a correction factor below "1", while temperatures below 60 °F correlate with a factor above "1". This concept lies in the basis for the kinetic theory of matter and thermal expansion of matter , which states as the temperature of a substance ...

  3. Compressibility factor - Wikipedia

    en.wikipedia.org/wiki/Compressibility_factor

    Compressibility factor values are usually obtained by calculation from equations of state (EOS), such as the virial equation which take compound-specific empirical constants as input. For a gas that is a mixture of two or more pure gases (air or natural gas, for example), the gas composition must be known before compressibility can be calculated.

  4. Gas/oil ratio - Wikipedia

    en.wikipedia.org/wiki/Gas/oil_ratio

    Definition of formation volume factor Bo and gas/oil ratio Rs for oil. When oil is produced to surface temperature and pressure it is usual for some natural gas to come out of solution. The gas/oil ratio (GOR) is the ratio of the volume of gas ("scf") that comes out of solution to the volume of oil — at standard conditions.

  5. Volume units used in petroleum engineering - Wikipedia

    en.wikipedia.org/wiki/Volume_units_used_in...

    Oil conversion factor from m³ to bbl (or stb) is 6.28981100 Gas conversion factor from standard m³ to scf is 35.314666721 Note that the m³ gas conversion factor takes into account a difference in the standard temperature base for measurement of gas volumes in metric and imperial units.

  6. Dropping point - Wikipedia

    en.wikipedia.org/wiki/Dropping_point

    The heat is reduced until the test tube temperature is at most 4 °F (2.2 °C) less than the oil/block temperature. Once the temperature has stabilized the sample is inserted. The dropping point is the temperature recorded on the test tube thermometer, plus a correction factor for the oil/block temperature, when a drop of grease falls through ...

  7. Logarithmic mean temperature difference - Wikipedia

    en.wikipedia.org/wiki/Logarithmic_mean...

    In thermal engineering, the logarithmic mean temperature difference (LMTD) is used to determine the temperature driving force for heat transfer in flow systems, most notably in heat exchangers. The LMTD is a logarithmic average of the temperature difference between the hot and cold feeds at each end of the double pipe exchanger.

  8. Temperature dependence of viscosity - Wikipedia

    en.wikipedia.org/wiki/Temperature_dependence_of...

    Increasing temperature results in a decrease in viscosity because a larger temperature means particles have greater thermal energy and are more easily able to overcome the attractive forces binding them together. An everyday example of this viscosity decrease is cooking oil moving more fluidly in a hot frying pan than in a cold one.

  9. NTU method - Wikipedia

    en.wikipedia.org/wiki/NTU_Method

    The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD). Alternatively, this method is useful for determining the expected heat ...