Search results
Results from the WOW.Com Content Network
Large crack-widths (greater than 0.3 mm) permit ingress of moisture and chemical attack to the concrete, resulting in possible corrosion of reinforcement and deterioration of concrete. Therefore, thick covers defeat the very purpose for which it is provided. There is a need for judicious balance of cover depth and crack width requirements.
3 Code of Practices for plain and reinforced concrete etc. IS 456 – 2000 4 Methods of sampling and analysis of concrete IS 1199 – 1959 5 Recommended Guide Lines for Concrete Mix Design IS 10262 – 1982 (F) Curing Compound; 1 Standard test method for water retention & daylight reflection test on concrete. ASTM-C-156809
Reinforced concrete, also called ferroconcrete, is a composite material in which concrete's relatively low tensile strength and ductility are compensated for by the inclusion of reinforcement having higher tensile strength or ductility.
EN 1992-1-2 deals with the design of concrete structures for the accidental situation of fire exposure and is intended to be used in conjunction with EN 1992-1-1 and EN 1991-1-2. This part 1-2 only identifies differences from, or supplements to, normal temperature design. Part 1-2 of EN 1992 deals only with passive methods of fire protection.
Once this is defined, design code gives standard prescriptions for w/c ratio, the cement content, and the thickness of the concrete cover. This approach represents an improvement step for the durability design of reinforced concrete structures, it is suitable for the design of ordinary structures designed with traditional materials (Portland ...
The strength enhancing effects of arching action in reinforced concrete floors were first recognised near the beginning of last century. [1] However, it was not until the full scale destructive load tests by Ockleston [2] [3] on the Old Dental Hospital in Johannesburg that the extent of strength enhancement caused by arching action was really ...
The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1] Reinforced concrete is the most common form of concrete. The reinforcement is often steel rebar (mesh, spiral, bars and other forms). Structural fibers of various materials are available.
ISMB: Indian Standard Medium Weight Beam, ISJB: Indian Standard Junior Beams, ISLB: Indian Standard Light Weight Beams, and ISWB: Indian Standard Wide Flange Beams. Beams are designated as per respective abbreviated reference followed by the depth of section, such as for example ISMB 450, where 450 is the depth of section in millimetres (mm ...