Search results
Results from the WOW.Com Content Network
The cation transport number of the leading solution is then calculated as t + = z + c L A F I Δ t {\displaystyle t_{+}={\frac {z_{+}cLAF}{I\Delta t}}} where z + {\displaystyle z_{+}} is the cation charge, c the concentration, L the distance moved by the boundary in time Δ t , A the cross-sectional area, F the Faraday constant , and I the ...
The Scatchard equation is an equation used in molecular biology to calculate the affinity and number of binding sites of a receptor for a ligand. [1] It is named after the American chemist George Scatchard.
Particle-Induced X-Ray Emission or Proton-Induced X-Ray Emission (PIXE) is a technique used for determining the elemental composition of a material or a sample.When a material is exposed to an ion beam, atomic interactions occur that give off EM radiation of wavelengths in the x-ray part of the electromagnetic spectrum specific to an element.
For hydrocarbons, the DBE (or IHD) tells us the number of rings and/or extra bonds in a non-saturated structure, which equals the number of hydrogen pairs that are required to make the structure saturated, simply because joining two elements to form a ring or adding one extra bond (e.g., a single bond changed to a double bond) in a structure reduces the need for two H's.
For typical ionic solids, the cations are smaller than the anions, and each cation is surrounded by coordinated anions which form a polyhedron.The sum of the ionic radii determines the cation-anion distance, while the cation-anion radius ratio + / (or /) determines the coordination number (C.N.) of the cation, as well as the shape of the coordinated polyhedron of anions.
In chemistry a donor number (DN) is a quantitative measure of Lewis basicity.A donor number is defined as the negative enthalpy value for the 1:1 adduct formation between a Lewis base and the standard Lewis acid SbCl 5 (antimony pentachloride), in dilute solution in the noncoordinating solvent 1,2-dichloroethane with a zero DN.
Bragg diffraction (also referred to as the Bragg formulation of X-ray diffraction) was first proposed by Lawrence Bragg and his father, William Henry Bragg, in 1913 [1] after their discovery that crystalline solids produced surprising patterns of reflected X-rays (in contrast to those produced with, for instance, a liquid).
With the falling number test, so-called weather- or sprout-damaged wheat or rye, which adversely affects bread-making quality, could be detected at the grain silo intake within a few minutes. Sprouting , or pre-harvest germination , is caused by damp or rainy weather conditions during the final stage of maturation of the crop.