enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Switchgear - Wikipedia

    en.wikipedia.org/wiki/Switchgear

    Tram switchgear This circuit breaker uses both SF 6 and air as insulation. In an electric power system, a switchgear is composed of electrical disconnect switches, fuses or circuit breakers used to control, protect and isolate electrical equipment. Switchgear is used both to de-energize equipment to allow work to be done and to clear faults ...

  3. Ring main unit - Wikipedia

    en.wikipedia.org/wiki/Ring_main_unit

    In an electrical power distribution system, a ring main unit (RMU) is a factory assembled, metal enclosed set of switchgear used at the load connection points of a ring-type distribution network. It includes in one unit two switches that can connect the load to either or both main conductors, and a fusible switch or circuit breaker and switch ...

  4. Busbar - Wikipedia

    en.wikipedia.org/wiki/Busbar

    In electric power distribution, a busbar (also bus bar) is a metallic strip or bar, typically housed inside switchgear, panel boards, and busway enclosures for local high current power distribution. They are also used to connect high voltage equipment at electrical switchyards, and low-voltage equipment in battery banks .

  5. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Reclosers are often used as a key component in a smart grid, as they are effectively computer controlled switchgear which can be remotely operated and interrogated using supervisory control and data acquisition (SCADA) or other communications. Interrogation and remote operation capabilities allow utilities to aggregate data about their network ...

  6. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  7. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    This assembly, known as bus duct or busway, can be used for connections to large switchgear or for bringing the main power feed into a building. A form of bus duct known as "plug-in bus" is used to distribute power down the length of a building; it is constructed to allow tap-off switches or motor controllers to be installed at designated ...

  8. High-voltage switchgear - Wikipedia

    en.wikipedia.org/wiki/High-voltage_switchgear

    High-voltage switchgear is any switchgear used to connect or disconnect a part of a high-voltage power system. This equipment is essential for the protection and safe operation, without interruption, of a high voltage power system, and is important because it is directly linked to the quality of the electricity supply.

  9. Relay logic - Wikipedia

    en.wikipedia.org/wiki/Relay_logic

    A number strip would be peeled out and wrapped around the wire near the end. Wire numbers were made up of a series of the number strips so wire 1051 would be four strips. There are also pocket sized printers that print onto an adhesive backed label that can be wrapped around the wire. The basic format for relay logic diagrams is as follows: 1.