Glucose vs. plasma glucose: Glucose levels in plasma (one of the components of blood) are higher than glucose measurements in whole blood; the difference is about 11% when the hematocrit is normal. This is important because home blood glucose meters measure the glucose in whole blood while most lab tests measure the glucose in plasma.
Four generations of blood glucose meter, c. 1991–2005. Sample sizes vary from 30 to 0.3 μl. Test times vary from 5 seconds to 2 minutes (modern meters typically require less than 15 seconds). A blood glucose meter is an electronic device for measuring the blood glucose level. A relatively small drop of blood is placed on a disposable test ...
More generally, in the medical literature, the Pasteur effect refers to how the cellular presence of oxygen causes in cells a decrease in the rate of glycolysis and also a suppression of lactate accumulation. The effect occurs in animal tissues, as well as in microorganisms belonging to the fungal kingdom. [2] [3]
The osmol gap is typically calculated with the following formula (all values in mmol/L): = = ([+] + [] + []) In non-SI laboratory units: Calculated osmolality = 2 x [Na mmol/L] + [glucose mg/dL] / 18 + [BUN mg/dL] / 2.8 + [ethanol/3.7] [3] (note: the values 18 and 2.8 convert mg/dL into mmol/L; the molecular weight of ethanol is 46, but empiric data shows that it does not act as an ideal ...
Hyperglycemic clamp technique: The plasma glucose concentration is acutely raised to 125 mg/dl above basal levels by a continuous infusion of glucose. This hyperglycemic plateau is maintained by adjustment of a variable glucose infusion, based on the rate of insulin secretion and glucose metabolism. Because the plasma glucose concentration is ...
For a 2 hour GTT with 75 g intake, a glucose level below 7.8 mmol/L (140 mg/dL) is normal, whereas higher levels indicate hyperglycemia. Blood plasma glucose between 7.8 mmol/L (140 mg/dL) and 11.1 mmol/L (200 mg/dL) indicate " impaired glucose tolerance ", and levels at or above 11.1 mmol/L at 2 hours confirm a diagnosis of diabetes.
The Ames Reflectance Meter was the first blood glucose meter. It allowed patients with diabetes to self-monitor their blood glucose levels. The Ames Reflectance Meter was developed in 1970 by Anton H. Clemens. It had a needle that indicated the intensity of blue light reflected from a paper strip, called Dextrostix. The meter gave a ...
A1c is a weighted average of blood glucose levels during the life of the red blood cells (117 days for men and 106 days in women [18]). Therefore, glucose levels on days nearer to the test contribute substantially more to the level of A1c than the levels in days further from the test. [19]