Search results
Results from the WOW.Com Content Network
Self-starting polyphase induction motors produce torque even at standstill. Available squirrel-cage induction motor starting methods include direct-on-line starting, reduced-voltage reactor or auto-transformer starting, star-delta starting or, increasingly, new solid-state soft assemblies and, of course, variable frequency drives (VFDs). [39]
Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.
From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found. It is very important to know a motor's starting torque since if it is not enough to overcome the initial friction of its intended load then it will remain stationary while drawing an ...
A capacitor start motor is a split-phase induction motor with a starting motor capacitor inserted in series with the startup winding, creating an LC circuit which produces a greater phase shift (and so, a much greater starting torque) than both split-phase and shaded pole motors. This motor has a centrifugal switch which disconnects the ...
An induction motor draws very high starting current during its acceleration to full rated speed, typically 6 to 10 times the full load current. Reduced starting current is desirable where the electrical grid is not of sufficient capacity, or where the driven load cannot withstand high starting torque.
By adjusting the shape of the bars in the rotor, the speed-torque characteristics of the motor can be changed, to minimize starting current or to maximize low-speed torque, for example. Squirrel-cage induction motors are very prevalent in industry, in sizes from below 1 kilowatt (1.3 hp) up to tens of megawatts (tens-of-thousand horsepower).
The light may dim briefly as the motor starts. When the armature is not turning (called locked rotor) there is no back-EMF and the motor's current draw is quite high. If the motor's starting current is high enough, it will pull the line voltage down enough to cause noticeable dimming of the light.
As a result, the inrush current is reduced. Another important advantage over squirrel-cage motors is higher starting torque. The speed and torque characteristics of a wound-rotor motor can be adjusted by changing the external resistance, unlike a squirrel cage motor which has a fixed characteristic. This is useful for speed control of the motor ...