Search results
Results from the WOW.Com Content Network
Arc flash will be minimized if a pre-charge function slows down the activation time of a high voltage power-up. A slow pre-charge will also reduce the voltage into a faulty circuit which builds up while the system diagnostics come on-line. This allows a diagnostic shut down before the fault is fully realized in worst case proportions.
In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.
For example, the power-handling ability of a resistor may be greatly derated when applied in high-altitude aircraft to obtain adequate service life. A sudden fail-open fault can cause multiple secondary failures if it is fast and the circuit contains an inductance ; this causes large voltage spikes , which may exceed 500 volts.
A bricked device may not power on at all, or it may power on, but never boot to the OS or firmware, the closest getting to a warning screen. Some kernel bugs [ ambiguous ] have been known that affect the /data partition in the eMMC chip, which becomes corrupted during certain operations such as wiping and flashing.
[21] [22] On 28 February 2020, Apple agreed to a $500 million settlement in a California court, under which it plans to pay at least $25 to all U.S. residents who had purchased an iPhone 6, 6 Plus, 6S, 6S Plus, SE, 7 or 7 Plus device . [23] A separate investigation from 34 states and the District of Columbia also looked into the battery practice.
Ambient temperature affects the time delay but does not affect the current rating of a magnetic breaker. [12] A large power circuit breaker, such as one applied in circuits of more than 1000 volts, may incorporate hydraulic elements in the contact operating mechanism. Hydraulic energy may be supplied by a pump or stored in accumulators.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
An arc-fault circuit interrupter (AFCI) or arc-fault detection device (AFDD) [1] is a circuit breaker that breaks the circuit when it detects the electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.