  2. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    During winter months, for example, an air conditioning register can be closed to prevent cold air from being pulled from the room. This allows the hot air to mix more completely with the cold air in the room, improving the efficiency of the HVAC system. [7] (The return should be efficient enough to draw off the cooler air.) [10] [11]

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load. These include the global coordinates of the site and the size of the structure. [1] [5]

  4. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Air returns from the room at ceiling level or the maximum allowable height above the occupied zone. [1] The UFAD system takes advantage of the thermal plume and stratification phenomenon: the conditioned air is supplied directly to the occupied zone (OZ). The thermal plumes generated by the occupants and other heat sources introduce the ...

  5. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Supply diffusers in the ceiling are fed by fan coil units in the ceiling void or by air handling units in a remote plant room. The fan coil or handling unit takes in return air from the ceiling void and mix this with fresh air and cool, or heat it, as required to achieve the room design conditions. This arrangement is known as 'conventional ...

  6. Uniform Mechanical Code - Wikipedia

    en.wikipedia.org/wiki/Uniform_Mechanical_Code

    The Uniform Mechanical Code (UMC) is a model code developed by the International Association of Plumbing and Mechanical Officials to govern the installation, inspection and maintenance of HVAC (heating, ventilating and air-conditioning) and refrigeration systems. It is designated as an American National Standard.

  7. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    A duct with less than 0.75 mg/100m 2 is considered to be clean, per the NADCA standard. [7] A Hong Kong standard lists surface deposit limits of 1g/m 2 for supply and return ducts and 6g/m 2 for exhaust ducts, or a maximum deposit thickness of 60 μm in supply and return ducts, and 180 μm for exhaust ducts. [8]

  8. Plenum space - Wikipedia

    en.wikipedia.org/wiki/Plenum_space

    A plenum space is a part of a building that can facilitate air circulation for heating and air conditioning systems, by providing pathways for either heated/conditioned or return airflows, usually at greater than atmospheric pressure.

  9. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).